Measurement Matters: A Metrological Approach to Renal Preimplantation Biopsy Evaluation to Address Uncertainty in Organ Selection.

BACKGROUND: Preimplantation biopsy combines measurements of injury into a composite index to inform organ acceptance. The uncertainty in these measurements remains poorly characterized, raising concerns variability may contribute to inappropriate clinical decisions. METHODS: We adopted a metrological approach to evaluate biopsy score reliability. Variability was assessed by performing repeat biopsies (n = 293) on discarded allografts (n = 16) using 3 methods (core, punch, and wedge). Uncertainty was quantified using a bootstrapping analysis. Observer effects were controlled by semi-blinded scoring, and the findings were validated by comparison with standard glass evaluation. RESULTS: The surgical method strongly determined the size (core biopsy area 9.04 mm2, wedge 37.9 mm2) and, therefore, yield (glomerular yield r = 0.94, arterial r = 0.62) of each biopsy. Core biopsies yielded inadequate slides most frequently. Repeat biopsy of the same kidney led to marked variation in biopsy scores. In 10 of 16 cases, scores were contradictory, crossing at least 1 decision boundary (ie, to transplant or to discard). Bootstrapping demonstrated significant uncertainty associated with single-slide assessment; however, scores were similar for paired kidneys from the same donor. CONCLUSIONS: Our investigation highlights the risks of relying on single-slide assessment to quantify organ injury. Biopsy evaluation is subject to uncertainty, meaning each slide is better conceptualized as providing an estimate of the kidney's condition rather than a definitive result. Pooling multiple assessments could improve the reliability of biopsy analysis, enhancing confidence. Where histological quantification is necessary, clinicians should seek to develop new protocols using more tissue and consider automated methods to assist pathologists in delivering analysis within clinical time frames.

Publication Details

Journal
Apollo (University of Cambridge)
Published
2024-08-10
DOI
https://doi.org/10.17863/cam.111209
Citations
1
Primary Topic
Renal Transplantation Outcomes and Treatments
Type
article
Field-Weighted Citation Impact
0.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement Matters: A Metrological Approach to Renal Preimplantation Biopsy Evaluation to Address Uncertainty in Organ Selection.

1 citations
Apollo (University of Cambridge)
Renal Transplantation Outcomes and Treatments
0.51
article

Measurement Matters: A Metrological Approach to Renal Preimplantation Biopsy Evaluation to Address Uncertainty in Organ Selection.

article en
1 citations

Abstract

BACKGROUND: Preimplantation biopsy combines measurements of injury into a composite index to inform organ acceptance. The uncertainty in these measurements remains poorly characterized, raising concerns variability may contribute to inappropriate clinical decisions. METHODS: We adopted a metrological approach to evaluate biopsy score reliability. Variability was assessed by performing repeat biopsies (n = 293) on discarded allografts (n = 16) using 3 methods (core, punch, and wedge). Uncertainty was quantified using a bootstrapping analysis. Observer effects were controlled by semi-blinded scoring, and the findings were validated by comparison with standard glass evaluation. RESULTS: The surgical method strongly determined the size (core biopsy area 9.04 mm2, wedge 37.9 mm2) and, therefore, yield (glomerular yield r = 0.94, arterial r = 0.62) of each biopsy. Core biopsies yielded inadequate slides most frequently. Repeat biopsy of the same kidney led to marked variation in biopsy scores. In 10 of 16 cases, scores were contradictory, crossing at least 1 decision boundary (ie, to transplant or to discard). Bootstrapping demonstrated significant uncertainty associated with single-slide assessment; however, scores were similar for paired kidneys from the same donor. CONCLUSIONS: Our investigation highlights the risks of relying on single-slide assessment to quantify organ injury. Biopsy evaluation is subject to uncertainty, meaning each slide is better conceptualized as providing an estimate of the kidney's condition rather than a definitive result. Pooling multiple assessments could improve the reliability of biopsy analysis, enhancing confidence. Where histological quantification is necessary, clinicians should seek to develop new protocols using more tissue and consider automated methods to assist pathologists in delivering analysis within clinical time frames.

Apollo (University of Cambridge)
Government of the United Kingdom, Medical Research Council
Good health and well-being
Openalex Percentile: Top 30%
Renal Transplantation Outcomes and Treatments
0.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.