Non-destructive beam profile measurements with an Ionisation Profile Monitor (IPM) based on Timepix3&4 Hybrid Pixel Detectors (HPDs)

Beam Gas Ionization monitors have been in operational use in the CERN PS for two years now, and they were installed in the SPS this year. An overview of the operating principal of the instruments is presented, followed by an update on their development. The mechanical design has been simplified and the Timepix3 devices are now mounted individually for easier assembly and maintenance. Reliability and availability have been improved with a new radiation-hard readout, using the GBTx and bPOL12 devices. Performance has been improved with a SoC Back-End making good use of both the FPGA and the Processing System. We have worked to improve the calibration of the instruments, equalization can now be performed in-situ and we have a procedure to calibrate the response between the four detectors. This paper also presents some example results from the instruments and describes our plans for future developments.

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.18429/jacow-ibic2024-wep15
Citations
1
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-destructive beam profile measurements with an Ionisation Profile Monitor (IPM) based on Timepix3&4 Hybrid Pixel Detectors (HPDs)

1 citations
Particle Detector Development and Performance
0.66
article

Non-destructive beam profile measurements with an Ionisation Profile Monitor (IPM) based on Timepix3&4 Hybrid Pixel Detectors (HPDs)

article en
1 citations

Abstract

Beam Gas Ionization monitors have been in operational use in the CERN PS for two years now, and they were installed in the SPS this year. An overview of the operating principal of the instruments is presented, followed by an update on their development. The mechanical design has been simplified and the Timepix3 devices are now mounted individually for easier assembly and maintenance. Reliability and availability have been improved with a new radiation-hard readout, using the GBTx and bPOL12 devices. Performance has been improved with a SoC Back-End making good use of both the FPGA and the Processing System. We have worked to improve the calibration of the instruments, equalization can now be performed in-situ and we have a procedure to calibrate the response between the four detectors. This paper also presents some example results from the instruments and describes our plans for future developments.

Affordable and clean energy
Openalex Percentile: Top 13%
Particle Detector Development and Performance
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.