RF tuning analysis of a 750 MHz carbon RFQ for medical applications

This work is part of the development study of a linac injector for hadron therapy with carbon ion beams. The initial cavities of the future injector consist of two 750 MHz Radio Frequency Quadrupoles (RFQ), which are based on the compact CERN High-Frequency RFQ. These RFQs are designed to accelerate the ions from 15 KeV/u to 5 MeV/u. Each RFQ, with a length of more of 2 meters, comprises four individual modules and 32 tuners, 8 per module. Certain design choices, manufacturing imperfections, and misalignments lead to local variations in the frequency and field distribution within the RFQs. The tuning procedure corrects these perturbations in the TE210 operating mode using a bead pull system and movable tuners. The aim of this article is to determine the maximum field correction achieved through this tuning without affecting the beam dynamics. For this purpose, a set of electromagnetic deviations that introduces significant dipole components to the cavity is simulated, using CST Studio. Using the tuning algorithm, this EM deviation is corrected in a realistic way.

Institutions

Publication Details

Journal
JACOW
Published
2024-10-25
DOI
https://doi.org/10.18429/jacow-linac2024-mopb016
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RF tuning analysis of a 750 MHz carbon RFQ for medical applications

JACOW
Particle accelerators and beam dynamics
article

RF tuning analysis of a 750 MHz carbon RFQ for medical applications

article en

Abstract

This work is part of the development study of a linac injector for hadron therapy with carbon ion beams. The initial cavities of the future injector consist of two 750 MHz Radio Frequency Quadrupoles (RFQ), which are based on the compact CERN High-Frequency RFQ. These RFQs are designed to accelerate the ions from 15 KeV/u to 5 MeV/u. Each RFQ, with a length of more of 2 meters, comprises four individual modules and 32 tuners, 8 per module. Certain design choices, manufacturing imperfections, and misalignments lead to local variations in the frequency and field distribution within the RFQs. The tuning procedure corrects these perturbations in the TE210 operating mode using a bead pull system and movable tuners. The aim of this article is to determine the maximum field correction achieved through this tuning without affecting the beam dynamics. For this purpose, a set of electromagnetic deviations that introduces significant dipole components to the cavity is simulated, using CST Studio. Using the tuning algorithm, this EM deviation is corrected in a realistic way.

JACOW
Instituto de Ciencia de Materiales de Madrid (ES), Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (ES), European Organization for Nuclear Research (CH)
Openalex Percentile: Top 40%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.