High Q and high gradient performance of the first medium-temperature baking 1.3 GHz cryomodule

The world’s first 1.3 GHz cryomodule containing eight 9-cell superconducting radio-frequency (RF) cavities treated by medium-temperature furnace baking (mid-T bake) was developed, assembled and tested at the Institute of High Energy Physics (IHEP), Chinese Academy of Sciences for the Dalian Advanced Light Source (DALS). The 9-cell cavities in the cryomodule achieved an unprecedented high average intrinsic quality factor (Q0) of 3.8E10 at 16 MV/m and 3.6E10 at 21 MV/m in the horizontal test. The cryomodule can operate stably up to a total continuous wave (CW) RF voltage greater than 191 MV, with an average cavity usable accelerating gradient of more than 23 MV/m. The results significantly exceed the specifications of DALS and the other high repetition rate free electron laser facilities (LCLS-II, LCLS-II-HE, SHINE, S3FEL etc.). This paper reviews the cryomodule performance and discusses some important issues in cryomodule assembly and testing.

Institutions

Publication Details

Journal
JACOW
Published
2024-10-25
DOI
https://doi.org/10.18429/jacow-linac2024-moaa003
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High Q and high gradient performance of the first medium-temperature baking 1.3 GHz cryomodule

JACOW
Particle accelerators and beam dynamics
article

High Q and high gradient performance of the first medium-temperature baking 1.3 GHz cryomodule

article en

Abstract

The world’s first 1.3 GHz cryomodule containing eight 9-cell superconducting radio-frequency (RF) cavities treated by medium-temperature furnace baking (mid-T bake) was developed, assembled and tested at the Institute of High Energy Physics (IHEP), Chinese Academy of Sciences for the Dalian Advanced Light Source (DALS). The 9-cell cavities in the cryomodule achieved an unprecedented high average intrinsic quality factor (Q0) of 3.8E10 at 16 MV/m and 3.6E10 at 21 MV/m in the horizontal test. The cryomodule can operate stably up to a total continuous wave (CW) RF voltage greater than 191 MV, with an average cavity usable accelerating gradient of more than 23 MV/m. The results significantly exceed the specifications of DALS and the other high repetition rate free electron laser facilities (LCLS-II, LCLS-II-HE, SHINE, S3FEL etc.). This paper reviews the cryomodule performance and discusses some important issues in cryomodule assembly and testing.

JACOW
Chinese Academy of Sciences (CN)
Affordable and clean energy
Openalex Percentile: Top 40%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.