Measurement and Analysis of Gonadal Irradiation Dose During Singe-shot X-ray Exposure of Both Lower Limbs

Objective: To investigate the relationship between entrance surface dose (ESD) of gonads and physiological parameters such as sex, age, height, and weight in digital X-ray exposure of both lower limbs and to explore the feasibility of full-width long-plate imaging with single-dose radiation exposure. Methods: A total of 300 patients at a weight-bearing position of both lower limbs were prospectively enrolled in a hospital in Beijing, including 129 males and 171 females. The TLD detectors were set at the gonads on both sides of the patient during scanning. After exposure, the TLD detectors were measured with an RGD-3B thermoluminescence dosimeter, and the corresponding dose values were obtained and analyzed. Results: The average triple exposure dose (AP+bilateral view) in the full-length plate adult mode was (1281±202) µGy, which was approximately three times the single exposure dose (429±99) µGy. The triple exposure dose (AP+bilateral view) was significantly lower than the radiation dose recommended by international standards. Multiple linear regression analysis showed that only height and weight affected gonadal radiation dose. Under the scanning parameters of children, the ESD dose was (359±27) µGy and (627±155) µGy when the height was less or more than 160 cm, respectively, with a significant statistical difference. In adult mode, height and weight did not affect the ESD dose. Conclusions: This study showed that the exposure dose of gonads during full-length scanning of both lower limbs in a weight-bearing position with a single exposure was affected by height and weight. The dose received by the gonads was within the safe range, and a single exposure of the full-length plate radiation dose is feasible in clinical practice.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.15953/j.ctta.2023.171
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement and Analysis of Gonadal Irradiation Dose During Singe-shot X-ray Exposure of Both Lower Limbs

SHILAP Revista de lepidopterología
Radiation Dose and Imaging
article

Measurement and Analysis of Gonadal Irradiation Dose During Singe-shot X-ray Exposure of Both Lower Limbs

article en

Abstract

Objective: To investigate the relationship between entrance surface dose (ESD) of gonads and physiological parameters such as sex, age, height, and weight in digital X-ray exposure of both lower limbs and to explore the feasibility of full-width long-plate imaging with single-dose radiation exposure. Methods: A total of 300 patients at a weight-bearing position of both lower limbs were prospectively enrolled in a hospital in Beijing, including 129 males and 171 females. The TLD detectors were set at the gonads on both sides of the patient during scanning. After exposure, the TLD detectors were measured with an RGD-3B thermoluminescence dosimeter, and the corresponding dose values were obtained and analyzed. Results: The average triple exposure dose (AP+bilateral view) in the full-length plate adult mode was (1281±202) µGy, which was approximately three times the single exposure dose (429±99) µGy. The triple exposure dose (AP+bilateral view) was significantly lower than the radiation dose recommended by international standards. Multiple linear regression analysis showed that only height and weight affected gonadal radiation dose. Under the scanning parameters of children, the ESD dose was (359±27) µGy and (627±155) µGy when the height was less or more than 160 cm, respectively, with a significant statistical difference. In adult mode, height and weight did not affect the ESD dose. Conclusions: This study showed that the exposure dose of gonads during full-length scanning of both lower limbs in a weight-bearing position with a single exposure was affected by height and weight. The dose received by the gonads was within the safe range, and a single exposure of the full-length plate radiation dose is feasible in clinical practice.

SHILAP Revista de lepidopterología
Good health and well-being
Openalex Percentile: Top 52%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.