Eighteen-Month Hybrid Closed-Loop Use in Very Young Children With Type 1 Diabetes: A Single-Arm Multicenter Trial.

OBJECTIVE: We aimed to evaluate the longer-term safety and efficacy of hybrid closed-loop (CL) therapy in very young children with type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: Following a 16-week multinational, randomized crossover trial comparing hybrid CL with sensor-augmented pump (SAP) therapy in 74 very young children aged 1-7 years with T1D, participants were invited to an extension phase using CL for a further 18 months. Outcomes were compared with the primary-phase SAP period and primary-phase CL period. RESULTS: After the primary study phase, 60 participants were eligible to enroll in the extension. Of these, 49 consented (mean ± SD age 6.6 ± 1.5 years) to continue use of CL for 18 months. Percentage time in range (TIR) 3.9-10.0 mmol/L was 8.4 percentage points (95% CI 6.7-10.1; P < 0.001) higher, while HbA1c was 0.4% ([5.0 mmol/mol], 95% CI 0.3-0.6 [3.7-6.2]; P < 0.001) lower during the CL extension phase compared with primary-phase SAP period. At 18 months, mean HbA1c was 6.7 ± 0.5% and TIR was 70 ± 7%, compared with 6.7 ± 0.5% and 71 ± 6% in the primary-phase CL period. Time in hypoglycemia (<3.9 mmol/L) was similar between CL extension phase and both primary-phase SAP (P = 0.31) and CL periods (P = 0.70). There were two severe hypoglycemia events and one other serious adverse event during the extension phase. One unexpected serious adverse device effect occurred. CONCLUSIONS: Use of the Cambridge hybrid CL system led to sustained improvements in glycemic control lasting more than 18 months in very young children with T1D.

Publication Details

Journal
Apollo (University of Cambridge)
Published
2024-12-01
DOI
https://doi.org/10.17863/cam.114848
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Eighteen-Month Hybrid Closed-Loop Use in Very Young Children With Type 1 Diabetes: A Single-Arm Multicenter Trial.

Apollo (University of Cambridge)
Diabetes Management and Research
article

Eighteen-Month Hybrid Closed-Loop Use in Very Young Children With Type 1 Diabetes: A Single-Arm Multicenter Trial.

article en

Abstract

OBJECTIVE: We aimed to evaluate the longer-term safety and efficacy of hybrid closed-loop (CL) therapy in very young children with type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: Following a 16-week multinational, randomized crossover trial comparing hybrid CL with sensor-augmented pump (SAP) therapy in 74 very young children aged 1-7 years with T1D, participants were invited to an extension phase using CL for a further 18 months. Outcomes were compared with the primary-phase SAP period and primary-phase CL period. RESULTS: After the primary study phase, 60 participants were eligible to enroll in the extension. Of these, 49 consented (mean ± SD age 6.6 ± 1.5 years) to continue use of CL for 18 months. Percentage time in range (TIR) 3.9-10.0 mmol/L was 8.4 percentage points (95% CI 6.7-10.1; P < 0.001) higher, while HbA1c was 0.4% ([5.0 mmol/mol], 95% CI 0.3-0.6 [3.7-6.2]; P < 0.001) lower during the CL extension phase compared with primary-phase SAP period. At 18 months, mean HbA1c was 6.7 ± 0.5% and TIR was 70 ± 7%, compared with 6.7 ± 0.5% and 71 ± 6% in the primary-phase CL period. Time in hypoglycemia (<3.9 mmol/L) was similar between CL extension phase and both primary-phase SAP (P = 0.31) and CL periods (P = 0.70). There were two severe hypoglycemia events and one other serious adverse event during the extension phase. One unexpected serious adverse device effect occurred. CONCLUSIONS: Use of the Cambridge hybrid CL system led to sustained improvements in glycemic control lasting more than 18 months in very young children with T1D.

Apollo (University of Cambridge)
Wellcome Trust, Dexcom, National Institute for Health and Care Research, Department of Health and Social Care, European Commission, Horizon 2020 Framework Programme, NIHR Cambridge Biomedical Research Centre
Openalex Percentile: Top 55%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.