Study on consistency between liver fat fraction quantification based on photon-counting CT and MRI proton density fat fraction

Objective To investigate the consistency between CT-derived fat fraction (CT-FF) based on photon-counting CT material decomposition under different scanning conditions and magnetic resonance imaging proton density fat fraction (MRI-PDFF), thereby developing a CT-based method for liver fat quantification suitable for the Chinese population. Methods From September 2023 to February 2024, a total of 383 healthy volunteers were prospectively recruited at Ruijin Hospital, Shanghai Jiao Tong University School of Medicine (176 with PDFF < 5% and 207 with PDFF≥5%), and randomly assigned to four photon-counting CT scanning groups based on tube voltage (120 kVp/140 kVp) and radiation dose (standard dose/low dose). All subjects underwent photon-counting CT liver scanning and MRI examinations, with liver PDFF used as the reference standard for liver fat quantification. From the standard-dose group (n = 243), this study randomly selected 50 individuals each from the 120 kVp group (n = 123) and 140 kVp group (n = 120) to form a test cohort (n = 100), and the remaining subjects were assigned to the validation cohort (n = 283). Among volunteers with PDFF < 5% (n = 66) in the test cohort, this study randomly selected 20 individuals each from the 120 kVp group (n = 33) and 140 kVp group (n = 33) to form a threshold adjustment cohort (n = 40). The average CT values of liver and subcutaneous abdominal fat tissues were measured under low and high energy bins to serve as the thresholds for material decomposition. In the test cohort, the correlation and consistency between CT-FF and PDFF values obtained using thresholds before and after adjustment were compared. The performance of the adjusted threshold in measuring liver fat content was evaluated in the validation cohort, as well as the consistency across subgroups with different scanning protocols. Results Based on data from the threshold adjustment cohort, the average CT values of liver tissue at 120 kVp and 140 kVp were 65 HU and 70 HU in the low and high energy bins, respectively. For fat tissue, the average CT values in the low and high energy bins were -127 HU and -96 HU at 120 kVp, and -125 HU and -92 HU at 140 kVp, which were used as the density thresholds for material decomposition. In the test cohort, after threshold adjustment, the correlation (r, 0.98 vs. 0.77), consistency (ICC, 0.980 vs. 0.770; r², 0.96 vs. 0.60), and mean difference (-0.7% vs. -18.1%) between CT-FF and PDFF values were significantly improved. In the entire validation cohort and across subgroups with different tube voltages and radiation doses, CT-FF and PDFF showed excellent correlation and consistency (r = 0.99, P < 0.001, r² = 0.98, ICC = 0.99), with mean differences not exceeding -0.7%. Conclusion Based on the liver tissue characteristics of the Chinese population, this study optimizes the density thresholds of the photon-counting CT material decomposition algorithm, and develops a fat quantification correction standard applicable to Chinese individuals for the first time, significantly improving measurement accuracy. This method may provide a new non-invasive and precise approach for liver fat quantification.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.16150/j.1671-2870.2025.02.005
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on consistency between liver fat fraction quantification based on photon-counting CT and MRI proton density fat fraction

SHILAP Revista de lepidopterología
Radiomics and Machine Learning in Medical Imaging
article

Study on consistency between liver fat fraction quantification based on photon-counting CT and MRI proton density fat fraction

article en

Abstract

Objective To investigate the consistency between CT-derived fat fraction (CT-FF) based on photon-counting CT material decomposition under different scanning conditions and magnetic resonance imaging proton density fat fraction (MRI-PDFF), thereby developing a CT-based method for liver fat quantification suitable for the Chinese population. Methods From September 2023 to February 2024, a total of 383 healthy volunteers were prospectively recruited at Ruijin Hospital, Shanghai Jiao Tong University School of Medicine (176 with PDFF < 5% and 207 with PDFF≥5%), and randomly assigned to four photon-counting CT scanning groups based on tube voltage (120 kVp/140 kVp) and radiation dose (standard dose/low dose). All subjects underwent photon-counting CT liver scanning and MRI examinations, with liver PDFF used as the reference standard for liver fat quantification. From the standard-dose group (n = 243), this study randomly selected 50 individuals each from the 120 kVp group (n = 123) and 140 kVp group (n = 120) to form a test cohort (n = 100), and the remaining subjects were assigned to the validation cohort (n = 283). Among volunteers with PDFF < 5% (n = 66) in the test cohort, this study randomly selected 20 individuals each from the 120 kVp group (n = 33) and 140 kVp group (n = 33) to form a threshold adjustment cohort (n = 40). The average CT values of liver and subcutaneous abdominal fat tissues were measured under low and high energy bins to serve as the thresholds for material decomposition. In the test cohort, the correlation and consistency between CT-FF and PDFF values obtained using thresholds before and after adjustment were compared. The performance of the adjusted threshold in measuring liver fat content was evaluated in the validation cohort, as well as the consistency across subgroups with different scanning protocols. Results Based on data from the threshold adjustment cohort, the average CT values of liver tissue at 120 kVp and 140 kVp were 65 HU and 70 HU in the low and high energy bins, respectively. For fat tissue, the average CT values in the low and high energy bins were -127 HU and -96 HU at 120 kVp, and -125 HU and -92 HU at 140 kVp, which were used as the density thresholds for material decomposition. In the test cohort, after threshold adjustment, the correlation (r, 0.98 vs. 0.77), consistency (ICC, 0.980 vs. 0.770; r², 0.96 vs. 0.60), and mean difference (-0.7% vs. -18.1%) between CT-FF and PDFF values were significantly improved. In the entire validation cohort and across subgroups with different tube voltages and radiation doses, CT-FF and PDFF showed excellent correlation and consistency (r = 0.99, P < 0.001, r² = 0.98, ICC = 0.99), with mean differences not exceeding -0.7%. Conclusion Based on the liver tissue characteristics of the Chinese population, this study optimizes the density thresholds of the photon-counting CT material decomposition algorithm, and develops a fat quantification correction standard applicable to Chinese individuals for the first time, significantly improving measurement accuracy. This method may provide a new non-invasive and precise approach for liver fat quantification.

SHILAP Revista de lepidopterología
Ruijin Hospital (CN), Shanghai University of Medicine and Health Sciences (CN)
Openalex Percentile: Top 42%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.