Influence of Carbon Contact Strip Wear Profile on the Dynamic Performance of Pantograph-Catenary System

[Objective] The carbon contact strip abnormal wear profile will reduce the dynamic coupling performance of the pantograph-catenary (PC), deteriorate the current collection quality, and accelerate the wear of the carbon contact strip and the contact wire. In order to find out the key carbon contact strip wear parameters that deteriorate the PC dynamic contact performance, it is necessary to study the influence of the carbon contact strip wear profile on the PC dynamic performance. [Method] A rigid flexible hybrid dynamic model of the pantograph considering the carbon contact strip wear profile is established, to study the influence of different carbon contact strip wear profiles on the PC dynamic performance. The accuracy of the model is verified by the measured data of the subway line. On this basis, the carbon contact strip wear profile is modeled through the measured wear profile data of the carbon contact strip after wear, and the contact force response under different profiles is studied. [Result & Conclusion] The fundamental frequency of the span passing frequency and the multiple frequency of the pantograph vertical movement make a greater contribution to the not-in-service profile, and each frequency band has influence on the contact force for the profiles in service; when the height difference of carbon contact strip is less than 1.5 mm, the standard deviation and maximum value of the contact force increase rapidly; when the height difference of carbon contact strip is 1.5~3.0 mm, the standard deviation and maximum value of the contact force remain in relatively stable state; when the height difference of carbon contact strip exceeds 3.0 mm, the standard deviation and maximum value of the contact force increase rapidly, with the maximum value exceeding 300 N.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.16037/j.1007-869x.2025.04.009
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Carbon Contact Strip Wear Profile on the Dynamic Performance of Pantograph-Catenary System

SHILAP Revista de lepidopterología
Electrical Contact Performance and Analysis
article

Influence of Carbon Contact Strip Wear Profile on the Dynamic Performance of Pantograph-Catenary System

article en

Abstract

[Objective] The carbon contact strip abnormal wear profile will reduce the dynamic coupling performance of the pantograph-catenary (PC), deteriorate the current collection quality, and accelerate the wear of the carbon contact strip and the contact wire. In order to find out the key carbon contact strip wear parameters that deteriorate the PC dynamic contact performance, it is necessary to study the influence of the carbon contact strip wear profile on the PC dynamic performance. [Method] A rigid flexible hybrid dynamic model of the pantograph considering the carbon contact strip wear profile is established, to study the influence of different carbon contact strip wear profiles on the PC dynamic performance. The accuracy of the model is verified by the measured data of the subway line. On this basis, the carbon contact strip wear profile is modeled through the measured wear profile data of the carbon contact strip after wear, and the contact force response under different profiles is studied. [Result & Conclusion] The fundamental frequency of the span passing frequency and the multiple frequency of the pantograph vertical movement make a greater contribution to the not-in-service profile, and each frequency band has influence on the contact force for the profiles in service; when the height difference of carbon contact strip is less than 1.5 mm, the standard deviation and maximum value of the contact force increase rapidly; when the height difference of carbon contact strip is 1.5~3.0 mm, the standard deviation and maximum value of the contact force remain in relatively stable state; when the height difference of carbon contact strip exceeds 3.0 mm, the standard deviation and maximum value of the contact force increase rapidly, with the maximum value exceeding 300 N.

SHILAP Revista de lepidopterología
National Institute of Measurement and Testing Technology (CN), China Railway Group (China) (CN), Southwest Jiaotong University (CN)
Openalex Percentile: Top 56%
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.