Photon-counting CT in liver disease: applications and advances

Photon-counting computed tomography (PCCT) represents a significant technological breakthrough in the field of CT imaging in recent years. This innovative technology utilizes novel semiconductor detectors to directly detect and count individual X-ray photons, enabling high-precision multi-energy data acquisition. Compared with traditional energy-integrating detector CT (EID-CT), PCCT offers significant technical advantages, including ultra-high spatial resolution (with a minimum detector pixel size of 0.15×0.18 mm), improved contrast-to-noise ratio (CNR increase of 15%-45%), and substantial radiation dose reduction (20%-90%). Moreover, PCCT can generate standardized CT value images, ensu-ring stable and reproducible quantitative measurements suitable for tissue composition analysis. With its ability to acquire data across multiple energy bins, PCCT achieves true multi-energy spectral imaging. In liver diseases, PCCT enables non-enhanced quantification of hepatic fat and iron content, with 70 keV standardized CT values showing a strong correlation with MRI-derived proton density fat fraction (PDFF). During contrast-enhanced scans, PCCT significantly improves the detection rate and lesion margin delineation of hypovascular tumors and allows accurate enhancement quantification through iodine maps. Additionally, PCCT enables ultra-low-dose, one-stop imaging that simultaneously provides functional hemodynamic parameters of hepatic microcirculation and high-quality multiphasic monoenergetic CT images for clinical diagnosis and preoperative planning—without the need for additional contrast medium or supplementary triphasic scans. This dual benefit of low radiation and contrast dose supports its clinical utility in liver imaging. This review focuses on recent advances in the application of PCCT in the diagnosis and treatment of diffuse and neoplastic liver diseases, aiming to provide theoretical foundations and practical insights for its broader implementation in precision hepatology.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.16150/j.1671-2870.2025.02.002
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photon-counting CT in liver disease: applications and advances

SHILAP Revista de lepidopterología
Advanced X-ray and CT Imaging
article

Photon-counting CT in liver disease: applications and advances

article en

Abstract

Photon-counting computed tomography (PCCT) represents a significant technological breakthrough in the field of CT imaging in recent years. This innovative technology utilizes novel semiconductor detectors to directly detect and count individual X-ray photons, enabling high-precision multi-energy data acquisition. Compared with traditional energy-integrating detector CT (EID-CT), PCCT offers significant technical advantages, including ultra-high spatial resolution (with a minimum detector pixel size of 0.15×0.18 mm), improved contrast-to-noise ratio (CNR increase of 15%-45%), and substantial radiation dose reduction (20%-90%). Moreover, PCCT can generate standardized CT value images, ensu-ring stable and reproducible quantitative measurements suitable for tissue composition analysis. With its ability to acquire data across multiple energy bins, PCCT achieves true multi-energy spectral imaging. In liver diseases, PCCT enables non-enhanced quantification of hepatic fat and iron content, with 70 keV standardized CT values showing a strong correlation with MRI-derived proton density fat fraction (PDFF). During contrast-enhanced scans, PCCT significantly improves the detection rate and lesion margin delineation of hypovascular tumors and allows accurate enhancement quantification through iodine maps. Additionally, PCCT enables ultra-low-dose, one-stop imaging that simultaneously provides functional hemodynamic parameters of hepatic microcirculation and high-quality multiphasic monoenergetic CT images for clinical diagnosis and preoperative planning—without the need for additional contrast medium or supplementary triphasic scans. This dual benefit of low radiation and contrast dose supports its clinical utility in liver imaging. This review focuses on recent advances in the application of PCCT in the diagnosis and treatment of diffuse and neoplastic liver diseases, aiming to provide theoretical foundations and practical insights for its broader implementation in precision hepatology.

SHILAP Revista de lepidopterología
Ruijin Hospital (CN)
Affordable and clean energy
Openalex Percentile: Top 58%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.