A quantitative comparison of electrode positions for respiratory surface EMG

Objective: Respiratory surface electromyography (sEMG) is a promising physiological signal for analyzing respiratory effort, patient-ventilator asynchrony, and respiratory training. In clinical research, a wide variety of different setups are used and no consensus has yet been reached on the positioning of electrodes. Therefore, this work aims to quantitatively compare both unilateral and bilateral bipolar electrode leads. Methods: Recordings of diaphragmatic and intercostal muscle activity were performed in 20 young and healthy adults using a setup with 64 electrodes placed in relation to prominent anatomical lines. Subjects completed three breathing maneuvers: 300 s quiet breathing, 5 maximum inspiratory pressure (MIP) trials, and 15 breaths of resistance breathing at 20 % of the MIP. To quantify the performance of differential electrode leads, three metrics were determined: the ratio between inspiratory muscle activity and (1) baseline noise (SNRbase), (2) expiratory muscle activity (SNRexp), and (3) ECG interference (SNREMG-ECG). Results: The study revealed considerable differences between bipolar electrode positions. Our results support the use of bilateral positions on the midclavicular line and parasternal line for measuring diaphragm and intercostal activity. For intercostal muscles, there is a high flexibility in positioning electrodes more lateral or medial, if necessary. Unilateral leads do not appear to outperform the bilateral configuration as SNR metrics were consistently smaller. Conclusion: This study provides recommendations for electrode placements and is a first step towards standardization of respiratory sEMG measurements. Significance: This electrode lead standardization will be essential to increase clinical acceptance in the future.

Publication Details

Journal
TUHH Open Research
Published
2025-03-24
DOI
https://doi.org/10.15480/882.14948
Primary Topic
Chronic Obstructive Pulmonary Disease (COPD) Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A quantitative comparison of electrode positions for respiratory surface EMG

TUHH Open Research
Chronic Obstructive Pulmonary Disease (COPD) Research
article

A quantitative comparison of electrode positions for respiratory surface EMG

article en

Abstract

Objective: Respiratory surface electromyography (sEMG) is a promising physiological signal for analyzing respiratory effort, patient-ventilator asynchrony, and respiratory training. In clinical research, a wide variety of different setups are used and no consensus has yet been reached on the positioning of electrodes. Therefore, this work aims to quantitatively compare both unilateral and bilateral bipolar electrode leads. Methods: Recordings of diaphragmatic and intercostal muscle activity were performed in 20 young and healthy adults using a setup with 64 electrodes placed in relation to prominent anatomical lines. Subjects completed three breathing maneuvers: 300 s quiet breathing, 5 maximum inspiratory pressure (MIP) trials, and 15 breaths of resistance breathing at 20 % of the MIP. To quantify the performance of differential electrode leads, three metrics were determined: the ratio between inspiratory muscle activity and (1) baseline noise (SNRbase), (2) expiratory muscle activity (SNRexp), and (3) ECG interference (SNREMG-ECG). Results: The study revealed considerable differences between bipolar electrode positions. Our results support the use of bilateral positions on the midclavicular line and parasternal line for measuring diaphragm and intercostal activity. For intercostal muscles, there is a high flexibility in positioning electrodes more lateral or medial, if necessary. Unilateral leads do not appear to outperform the bilateral configuration as SNR metrics were consistently smaller. Conclusion: This study provides recommendations for electrode placements and is a first step towards standardization of respiratory sEMG measurements. Significance: This electrode lead standardization will be essential to increase clinical acceptance in the future.

TUHH Open Research
Good health and well-being
Openalex Percentile: Top 39%
Chronic Obstructive Pulmonary Disease (COPD) Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A quantitative comparison of electrode positions for respiratory surface EMG · TUHH Open Research (2025) | TGRS Research Map | TGRS