S1 File -

<div><p>Assessing glomerular filtration rate (GFR) is critical for diagnosis, staging, and management of kidney disease. However, accuracy of estimated GFR (eGFR) is limited by large errors (>30% error present in >10–50% of patients), adversely impacting patient care. Errors often result from variation across populations of non-GFR determinants affecting the filtration markers used to estimate GFR. We hypothesized that combining multiple filtration markers with non-overlapping non-GFR determinants into a panel GFR could improve eGFR accuracy, extending current recognition that adding cystatin C to serum creatinine improves accuracy. Non-GFR determinants of markers can affect the accuracy of eGFR in two ways: first, increased variability in the non-GFR determinants of some filtration markers among application populations compared to the development population may result in outlying values for those markers. Second, systematic differences in the non-GFR determinants of some markers between application and development populations can lead to biased estimates in the application populations. Here, we propose and evaluate methods for estimating GFR based on multiple markers in applications with potentially higher rates of outlying predictors than in development data. We apply transfer learning to address systematic differences between application and development populations. We evaluated a panel of 8 markers (5 metabolites and 3 low molecular weight proteins) in 3,554 participants from 9 studies. Results show that contamination in two strongly predictive markers can increase imprecision by more than two-fold, but outlier identification with robust estimation can restore precision nearly fully to uncontaminated data. Furthermore, transfer learning can yield similar results with even modest training set sample size. Combining both approaches addresses both sources of error in GFR estimates. Once the laboratory challenge of developing a validated targeted assay for additional metabolites is overcome, these methods can inform the use of a panel eGFR across diverse clinical settings, ensuring accuracy despite differing non-GFR determinants.</p></div>

Publication Details

Journal
Figshare
Published
2024-12-02
DOI
https://doi.org/10.1371/journal.pone.0313154.s001
Primary Topic
Chronic Kidney Disease and Diabetes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

S1 File -

Figshare
Chronic Kidney Disease and Diabetes
article

S1 File -

article en

Abstract

<div><p>Assessing glomerular filtration rate (GFR) is critical for diagnosis, staging, and management of kidney disease. However, accuracy of estimated GFR (eGFR) is limited by large errors (>30% error present in >10–50% of patients), adversely impacting patient care. Errors often result from variation across populations of non-GFR determinants affecting the filtration markers used to estimate GFR. We hypothesized that combining multiple filtration markers with non-overlapping non-GFR determinants into a panel GFR could improve eGFR accuracy, extending current recognition that adding cystatin C to serum creatinine improves accuracy. Non-GFR determinants of markers can affect the accuracy of eGFR in two ways: first, increased variability in the non-GFR determinants of some filtration markers among application populations compared to the development population may result in outlying values for those markers. Second, systematic differences in the non-GFR determinants of some markers between application and development populations can lead to biased estimates in the application populations. Here, we propose and evaluate methods for estimating GFR based on multiple markers in applications with potentially higher rates of outlying predictors than in development data. We apply transfer learning to address systematic differences between application and development populations. We evaluated a panel of 8 markers (5 metabolites and 3 low molecular weight proteins) in 3,554 participants from 9 studies. Results show that contamination in two strongly predictive markers can increase imprecision by more than two-fold, but outlier identification with robust estimation can restore precision nearly fully to uncontaminated data. Furthermore, transfer learning can yield similar results with even modest training set sample size. Combining both approaches addresses both sources of error in GFR estimates. Once the laboratory challenge of developing a validated targeted assay for additional metabolites is overcome, these methods can inform the use of a panel eGFR across diverse clinical settings, ensuring accuracy despite differing non-GFR determinants.</p></div>

Figshare
Openalex Percentile: Top 58%
Chronic Kidney Disease and Diabetes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.