Background phase induced steady‐state effects in velocity quantification using phase‐contrast MRI

Purpose: Flow quantification using phase‐contrast (PC) MRI is based on steady‐state gradient echo (GRE) sequences and is hampered by spatially varying background phase offsets. The purpose of this work was to investigate the effect of steady‐state disruptions during PC‐MRI GRE sequences on these background phases. Based on these findings, a specific sequence and timing is suggested, and caution is expressed when using typical correction algorithms. Methods: Steady‐state responses in stationary tissue were investigated in different prospectively triggered through‐plane phase‐contrast MRI sequence. Different spoiling methods (gradient spoiling/FISP versus gradient+RF spoiling/FLASH) and interleaving of flow encoding gradients (every TR vs. every ECG cycle) were investigated using simulations, in phantoms and in vivo. Additionally, the effect of relaxation times on the phase offsets was simulated and measured. The impact on image‐ and phantom‐based background phase correction was studied. Results: Good agreement between simulation and phantom measurements were observed. Different sequences lead to different spatiotemporal and tissue dependent background phases. Average flow rates in the popliteal artery were over‐ and underestimated for ECG‐interleaved and TR‐interleaved FISP acquisitions compared to FLASH, respectively. Conclusion: Background phase measurements are influenced by steady‐state effects leading to potentially false background phase quantification. Current background phase correction methods cannot correct for the disturbance.

Publication Details

Journal
DepositOnce
Published
2024-10-24
DOI
https://doi.org/10.14279/depositonce-23491
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Background phase induced steady‐state effects in velocity quantification using phase‐contrast MRI

DepositOnce
Advanced MRI Techniques and Applications
article

Background phase induced steady‐state effects in velocity quantification using phase‐contrast MRI

article en

Abstract

Purpose: Flow quantification using phase‐contrast (PC) MRI is based on steady‐state gradient echo (GRE) sequences and is hampered by spatially varying background phase offsets. The purpose of this work was to investigate the effect of steady‐state disruptions during PC‐MRI GRE sequences on these background phases. Based on these findings, a specific sequence and timing is suggested, and caution is expressed when using typical correction algorithms. Methods: Steady‐state responses in stationary tissue were investigated in different prospectively triggered through‐plane phase‐contrast MRI sequence. Different spoiling methods (gradient spoiling/FISP versus gradient+RF spoiling/FLASH) and interleaving of flow encoding gradients (every TR vs. every ECG cycle) were investigated using simulations, in phantoms and in vivo. Additionally, the effect of relaxation times on the phase offsets was simulated and measured. The impact on image‐ and phantom‐based background phase correction was studied. Results: Good agreement between simulation and phantom measurements were observed. Different sequences lead to different spatiotemporal and tissue dependent background phases. Average flow rates in the popliteal artery were over‐ and underestimated for ECG‐interleaved and TR‐interleaved FISP acquisitions compared to FLASH, respectively. Conclusion: Background phase measurements are influenced by steady‐state effects leading to potentially false background phase quantification. Current background phase correction methods cannot correct for the disturbance.

DepositOnce
Openalex Percentile: Top 52%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Background phase induced steady‐state effects in velocity quantification using phase‐contrast MRI · DepositOnce (2024) | TGRS Research Map | TGRS