Minimum data set

<div> Inclined piles are increasingly adopted in the foundation design of large-scale transmission line towers. Nine inclined pile tests were conducted in red clay soil to investigate the load-bearing and deformation behavior and the load transfer mechanism of inclined piles under vertical loading. The effects of pile inclination and length-to-diameter ratio on axial force, bending moment, shear force, and lateral friction force were analyzed. The test results indicate that: (1) As the inclination angle increases, the settlement of the inclined pile increases under vertical loading. (2) The axial force in the inclined pile is smaller compared to that of the corresponding vertical pile with the same material and dimensions. (3) Bending moment and shear force are observed in the upper section of the inclined pile, with the maximum bending moment influenced by both the pile’s inclination angle and length-to-diameter ratio. (4) In the upper section of the pile, the average soil-side frictional resistance of inclined piles is higher than that of vertical piles. The maximum resistance occurs in the section from the top of the pile to a relative depth (Z/L) of approximately 0.14. </div>

Publication Details

Journal
Figshare
Published
2025-03-27
DOI
https://doi.org/10.1371/journal.pone.0319849.s001
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Minimum data set

Figshare
High-Voltage Power Transmission Systems
article

Minimum data set

article en

Abstract

<div> Inclined piles are increasingly adopted in the foundation design of large-scale transmission line towers. Nine inclined pile tests were conducted in red clay soil to investigate the load-bearing and deformation behavior and the load transfer mechanism of inclined piles under vertical loading. The effects of pile inclination and length-to-diameter ratio on axial force, bending moment, shear force, and lateral friction force were analyzed. The test results indicate that: (1) As the inclination angle increases, the settlement of the inclined pile increases under vertical loading. (2) The axial force in the inclined pile is smaller compared to that of the corresponding vertical pile with the same material and dimensions. (3) Bending moment and shear force are observed in the upper section of the inclined pile, with the maximum bending moment influenced by both the pile’s inclination angle and length-to-diameter ratio. (4) In the upper section of the pile, the average soil-side frictional resistance of inclined piles is higher than that of vertical piles. The maximum resistance occurs in the section from the top of the pile to a relative depth (Z/L) of approximately 0.14. </div>

Figshare
Sustainable cities and communities
Openalex Percentile: Top 56%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.