Application of air cooled gas pump heat pipe compound cooling technology in energy storage power station

Existing energy storage plants currently employ traditional steam compression refrigeration, and the utilization ratio of natural cold sources requires enhancement. The introduction of air pump heat pipe technology can remedy this problem. According to the temperature control indicators of the air-cooled energy storage battery cabinet, the 20 kW air-cooled gas pump heat pipe composite air condition prototype was designed and the experimental study on the prototype performance was conducted. The testing methodology utilizes the enthalpy difference method, with the outdoor dry-bulb temperature controlled between -5 ℃ and 35 ℃. Data pertaining to the cooling capacity and power consumption of the prototype at 100% load are meticulously recorded for analysis. The results show:① lithium batteries work best in the range of 15~35 ℃, and during the charging/discharging process, excessive temperature difference between battery cells can cause series capacity mismatch, insufficient charging between parallel circuit batteries/clusters, and incomplete discharge; ② it is necessary to control the return air temperature of the air-cooled air condition in the energy storage battery cabinet to (25±1)℃; ③ under the same condenser and evaporator configuration, the energy efficiency ratio (EER) of traditional air-cooled air condition and gas pump heat pipe composite air condition is both 2.21 under outdoor operating conditions of 35 ℃, with the EER reaching 3.81 under outdoor operating conditions of 10 ℃, 5.63 under air pump heat pipe composite air condition, indicating good energy-saving potential; and ④ the tested technology is simple, reliable, and has good energy-saving advantages. Under all outdoor operating conditions, the annual energy efficiency ratio (AEER) of traditional air-cooled air condition is 3.31, while the AEER of air pump heat pipe composite air condition is 4.04.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.13338/j.issn.1674-649x.2024.05.013
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of air cooled gas pump heat pipe compound cooling technology in energy storage power station

SHILAP Revista de lepidopterología
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Application of air cooled gas pump heat pipe compound cooling technology in energy storage power station

article en

Abstract

Existing energy storage plants currently employ traditional steam compression refrigeration, and the utilization ratio of natural cold sources requires enhancement. The introduction of air pump heat pipe technology can remedy this problem. According to the temperature control indicators of the air-cooled energy storage battery cabinet, the 20 kW air-cooled gas pump heat pipe composite air condition prototype was designed and the experimental study on the prototype performance was conducted. The testing methodology utilizes the enthalpy difference method, with the outdoor dry-bulb temperature controlled between -5 ℃ and 35 ℃. Data pertaining to the cooling capacity and power consumption of the prototype at 100% load are meticulously recorded for analysis. The results show:① lithium batteries work best in the range of 15~35 ℃, and during the charging/discharging process, excessive temperature difference between battery cells can cause series capacity mismatch, insufficient charging between parallel circuit batteries/clusters, and incomplete discharge; ② it is necessary to control the return air temperature of the air-cooled air condition in the energy storage battery cabinet to (25±1)℃; ③ under the same condenser and evaporator configuration, the energy efficiency ratio (EER) of traditional air-cooled air condition and gas pump heat pipe composite air condition is both 2.21 under outdoor operating conditions of 35 ℃, with the EER reaching 3.81 under outdoor operating conditions of 10 ℃, 5.63 under air pump heat pipe composite air condition, indicating good energy-saving potential; and ④ the tested technology is simple, reliable, and has good energy-saving advantages. Under all outdoor operating conditions, the annual energy efficiency ratio (AEER) of traditional air-cooled air condition is 3.31, while the AEER of air pump heat pipe composite air condition is 4.04.

SHILAP Revista de lepidopterología
Ningbo University of Technology (CN), Ningbo Science and Technology Bureau (CN), Huazhong University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 67%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application of air cooled gas pump heat pipe compound cooling technology in energy storage power station · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS