Investigation on the Recognition of Split Aflatoxin M1 Aptamer

In this work, AFM1 was chosen as the target, and the aptamer was split to solve the low sensitivity due to unstable structure of the aptamer. The recognition ability and specificity of the split aptamer were evaluated using electrochemical methods, and the binding mechanism was explored through the circular dichroism. The results showed that the split aptamer employing a 1:1 split mode exhibited the best performance in the recognition and specificity for AFM1. The circular dichroism spectrum remained unchanged. The positive peak intensity of the circular dichroism spectrum increased significantly and the negative peak moved and the intensity increased, which demonstrated that the conformation of the aptamer changed. The sensitivity was enhanced by employing split aptamers. Superior recognition elements for the construction of sensors was obtained by the fragmentation of intact aptamers. The investigation provides a new idea to enhance the sensitivity of the detection mehtods based on the apatamer.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.13386/j.issn1002-0306.2023110024
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation on the Recognition of Split Aflatoxin M1 Aptamer

SHILAP Revista de lepidopterología
Advanced biosensing and bioanalysis techniques
article

Investigation on the Recognition of Split Aflatoxin M1 Aptamer

article en

Abstract

In this work, AFM1 was chosen as the target, and the aptamer was split to solve the low sensitivity due to unstable structure of the aptamer. The recognition ability and specificity of the split aptamer were evaluated using electrochemical methods, and the binding mechanism was explored through the circular dichroism. The results showed that the split aptamer employing a 1:1 split mode exhibited the best performance in the recognition and specificity for AFM1. The circular dichroism spectrum remained unchanged. The positive peak intensity of the circular dichroism spectrum increased significantly and the negative peak moved and the intensity increased, which demonstrated that the conformation of the aptamer changed. The sensitivity was enhanced by employing split aptamers. Superior recognition elements for the construction of sensors was obtained by the fragmentation of intact aptamers. The investigation provides a new idea to enhance the sensitivity of the detection mehtods based on the apatamer.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 72%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.