Measurements of Fusion Yield on the Centrifugal Mirror Fusion Experiment

The Centrifugal Mirror Fusion Experiment (CMFX) at the University of Maryland, College Park is a rotating mirror device that utilizes a central cathode to generate a radial electric field which induces a strongly sheared azimuthal $E\times B$ flow to improve plasma confinement and stability. The fusion yield of CMFX plasmas is assessed by diagnosis of neutron emission for the first time. The total neutron yield is measured with two xylene (EJ-301) and deuterated-xylene (EJ-301D) liquid scintillator detectors absolutely calibrated with an in silico method. A larger xylene scintillator was cross-calibrated and used to measure the time dynamics of the fusion rate under various experimental conditions. A permanently installed $^3$He gas tube detector was independently calibrated with a Cf-252 neutron source to make total yield measurements and provide an independent validation of the scintillator calibration. An interpretive modeling framework was developed using the 0D code MCTrans++ (Schwartz et al 2024 JPP) to infer undiagnosed plasma parameters such as density, temperature, and confinement time. A peak neutron emission rate of 8.4$\times 10^{6}$ $\pm$ 7.0$\times 10^{5}$ was measured (neglecting modeling uncertainties), with an inferred triple product of 1.9~$\times~10^{17}$ $\mathrm{m^{-3}}$ keV s from 0D modeling.

Publication Details

Journal
Maryland Shared Open Access Repository (USMAI Consortium)
Published
2025-05-29
DOI
https://doi.org/10.13016/m2ldwj-8h8p
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurements of Fusion Yield on the Centrifugal Mirror Fusion Experiment

Maryland Shared Open Access Repository (USMAI Consortium)
Magnetic confinement fusion research
article

Measurements of Fusion Yield on the Centrifugal Mirror Fusion Experiment

article en

Abstract

The Centrifugal Mirror Fusion Experiment (CMFX) at the University of Maryland, College Park is a rotating mirror device that utilizes a central cathode to generate a radial electric field which induces a strongly sheared azimuthal $E\times B$ flow to improve plasma confinement and stability. The fusion yield of CMFX plasmas is assessed by diagnosis of neutron emission for the first time. The total neutron yield is measured with two xylene (EJ-301) and deuterated-xylene (EJ-301D) liquid scintillator detectors absolutely calibrated with an in silico method. A larger xylene scintillator was cross-calibrated and used to measure the time dynamics of the fusion rate under various experimental conditions. A permanently installed $^3$He gas tube detector was independently calibrated with a Cf-252 neutron source to make total yield measurements and provide an independent validation of the scintillator calibration. An interpretive modeling framework was developed using the 0D code MCTrans++ (Schwartz et al 2024 JPP) to infer undiagnosed plasma parameters such as density, temperature, and confinement time. A peak neutron emission rate of 8.4$\times 10^{6}$ $\pm$ 7.0$\times 10^{5}$ was measured (neglecting modeling uncertainties), with an inferred triple product of 1.9~$\times~10^{17}$ $\mathrm{m^{-3}}$ keV s from 0D modeling.

Maryland Shared Open Access Repository (USMAI Consortium)
Advanced Research Projects Agency - Energy, Advanced Research Projects Agency
Openalex Percentile: Top 80%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.