Sourceless efficiency calibration method for γ spectrum based on numerical analysis

BackgroundEfficiency calibration is an important prerequisite for γ-spectroscopy measurement, and its accuracy directly affects the reliability of measurement results. The commonly used efficiency calibration methods are active efficiency calibration based on experimental measurement and passive efficiency calibration based on Monte Carlo (MC) simulations.PurposeThis study aims to propose a sourceless efficiency calibration method for γ spectrum based on numerical analysis.MethodsBased on theoretical analysis and numerical calculation, a passive efficiency calibration method based on numerical analysis was established, and applied to a constructed geometric model for typical cylindrical LaBr3(Ce) and NaI(Tl) detector with a diameter and length of 3.8 cm. The γ-ray path trajectory inside the detector, relative position of the source and detector, and peak-to-total ratio were comprehensively analyzed. Efficiency formulas for radioactive point, surface, and volume radioactive sources were formulated. Then, a numerical integration program based on Simpson's algorithm was implemented in MATLAB to solve the numerical analytical formula, and applied to the calculation of detection efficiencies of the 3.8 cm cylindrical LaBr3(Ce) and NaI(Tl) detectors for isotropic 137Cs point, surface, and volume sources. The calculation was performed again by changing the position of the point source and the size of the surface and volume sources. Simultaneously, the Monte Carlo (MC) simulation software MCNP5 was employed to establish the physical model of the detector, and the F8 pulse amplitude card was used to calculate the detection efficiency of the detector for specific energy γ-rays. Finally, detection efficiency obtained by numerical calculation was compared with that of MC simulation to verify the efficiency of proposed sourceless efficiency calibration method for γ spectrum.ResultsCompared with the MC simulation results, the maximum error of numerical calculation does not exceed 3.5%, and the maximum relative errors of the point source efficiency, surface source efficiency and volume source efficiency are 3.26%, 3.33% and 3.36%, repectively, which proves the reliability and accuracy of the numerical analysis method in calculating the detection efficiency.ConclusionsThe passive efficiency calibration method proposed in this study is accurate and fast, avoids complicated MC simulation software, which tends to be difficult to understand and operate. Additionally, this work can be extended to the efficiency calibration of nuclear radiation detectors with different shapes, providing a new pathway for the efficiency calibration of detectors.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.11889/j.0253-3219.2024.hjs.47.090204
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sourceless efficiency calibration method for γ spectrum based on numerical analysis

SHILAP Revista de lepidopterología
Radiation Detection and Scintillator Technologies
article

Sourceless efficiency calibration method for γ spectrum based on numerical analysis

article en

Abstract

BackgroundEfficiency calibration is an important prerequisite for γ-spectroscopy measurement, and its accuracy directly affects the reliability of measurement results. The commonly used efficiency calibration methods are active efficiency calibration based on experimental measurement and passive efficiency calibration based on Monte Carlo (MC) simulations.PurposeThis study aims to propose a sourceless efficiency calibration method for γ spectrum based on numerical analysis.MethodsBased on theoretical analysis and numerical calculation, a passive efficiency calibration method based on numerical analysis was established, and applied to a constructed geometric model for typical cylindrical LaBr3(Ce) and NaI(Tl) detector with a diameter and length of 3.8 cm. The γ-ray path trajectory inside the detector, relative position of the source and detector, and peak-to-total ratio were comprehensively analyzed. Efficiency formulas for radioactive point, surface, and volume radioactive sources were formulated. Then, a numerical integration program based on Simpson's algorithm was implemented in MATLAB to solve the numerical analytical formula, and applied to the calculation of detection efficiencies of the 3.8 cm cylindrical LaBr3(Ce) and NaI(Tl) detectors for isotropic 137Cs point, surface, and volume sources. The calculation was performed again by changing the position of the point source and the size of the surface and volume sources. Simultaneously, the Monte Carlo (MC) simulation software MCNP5 was employed to establish the physical model of the detector, and the F8 pulse amplitude card was used to calculate the detection efficiency of the detector for specific energy γ-rays. Finally, detection efficiency obtained by numerical calculation was compared with that of MC simulation to verify the efficiency of proposed sourceless efficiency calibration method for γ spectrum.ResultsCompared with the MC simulation results, the maximum error of numerical calculation does not exceed 3.5%, and the maximum relative errors of the point source efficiency, surface source efficiency and volume source efficiency are 3.26%, 3.33% and 3.36%, repectively, which proves the reliability and accuracy of the numerical analysis method in calculating the detection efficiency.ConclusionsThe passive efficiency calibration method proposed in this study is accurate and fast, avoids complicated MC simulation software, which tends to be difficult to understand and operate. Additionally, this work can be extended to the efficiency calibration of nuclear radiation detectors with different shapes, providing a new pathway for the efficiency calibration of detectors.

SHILAP Revista de lepidopterología
Affordable and clean energy
Openalex Percentile: Top 61%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.