Total hip arthroplasty via the direct anterior approach using a conventional traction table and fluoroscopy: a safe and cost-effective technique

Introduction: Precise implant positioning during total hip arthroplasty (THA) is an important factor affecting dislocation rate and long-term implant survival. Although a special carbon fiber traction table for THA improves the accuracy of implant positioning, it is too expensive. We aimed to report the accuracy of cup positioning and complication rate in patients undergoing THA using a conventional noncarbon fiber traction table, which is generally used for osteosynthesis of femoral fractures. Methods: This retrospective study included 62 patients who received primary THA via the direct anterior approach using a conventional traction table with fluoroscopy between July 2022 and December 2023. Two observers recorded radiological outcomes using postoperative anteroposterior X-rays. The intraclass correlation coefficients of cup positioning angles were evaluated (inclination: 0.92, anteversion: 0.88 for intra-observer agreement; inclination: 0.91, anteversion: 0.84 for inter-observer agreement). Complications were defined as dislocation, periprosthetic fracture, ankle fracture, implant loosening, nerve injury, surgical site infection, deep vein thrombosis, and revision surgery for any reason. Results: Radiographic analysis showed an average cup inclination of 38.5° ± 4.3° (98.4% within Lewinnek’s safe zone). The average cup anteversion was 12.6° ± 4.6° (100% within Lewinnek’s safe zone). None of the patients experienced any complications. Discussion: A conventional traction table could be a feasible alternative to a carbon fiber traction table for performing THA via the direct anterior approach using fluoroscopy at general hospitals.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-11-19
DOI
https://doi.org/10.1051/sicotj/2024045/pdf
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Total hip arthroplasty via the direct anterior approach using a conventional traction table and fluoroscopy: a safe and cost-effective technique

Springer Link (Chiba Institute of Technology)
Orthopaedic implants and arthroplasty
article

Total hip arthroplasty via the direct anterior approach using a conventional traction table and fluoroscopy: a safe and cost-effective technique

article en

Abstract

Introduction: Precise implant positioning during total hip arthroplasty (THA) is an important factor affecting dislocation rate and long-term implant survival. Although a special carbon fiber traction table for THA improves the accuracy of implant positioning, it is too expensive. We aimed to report the accuracy of cup positioning and complication rate in patients undergoing THA using a conventional noncarbon fiber traction table, which is generally used for osteosynthesis of femoral fractures. Methods: This retrospective study included 62 patients who received primary THA via the direct anterior approach using a conventional traction table with fluoroscopy between July 2022 and December 2023. Two observers recorded radiological outcomes using postoperative anteroposterior X-rays. The intraclass correlation coefficients of cup positioning angles were evaluated (inclination: 0.92, anteversion: 0.88 for intra-observer agreement; inclination: 0.91, anteversion: 0.84 for inter-observer agreement). Complications were defined as dislocation, periprosthetic fracture, ankle fracture, implant loosening, nerve injury, surgical site infection, deep vein thrombosis, and revision surgery for any reason. Results: Radiographic analysis showed an average cup inclination of 38.5° ± 4.3° (98.4% within Lewinnek’s safe zone). The average cup anteversion was 12.6° ± 4.6° (100% within Lewinnek’s safe zone). None of the patients experienced any complications. Discussion: A conventional traction table could be a feasible alternative to a carbon fiber traction table for performing THA via the direct anterior approach using fluoroscopy at general hospitals.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 49%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.