Investigation of thermo-optical effects in a nonlinear ZnGeP

\nThis work is dedicated to investigating the thermo-optical effects in a nonlinear ZnGeP2 crystal during parametric generation. The stable regime of the laser resonator was determined. It was found that for a resonator length of 43 mm, a stable regime was observed for all focal lengths of the thermal lens induced in the crystal. However, increasing the resonator length to 183 mm, the stability zone of the cavity no longer extends to the entire range of focal lengths of the induced thermal lens. Thus, the resonator becomes unstable for focal lengths of the induced thermal lens f ≤ 150 mm, which leads to high intracavity losses and is an undesirable operating mode of the cavity. Therefore, the experimental work has shown that when creating systems based on parametric generators with ZnGeP2 crystals, it is essential to consider the effect of the induced thermal lens and perform calculations of the cavity stability.\n

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-11-20
DOI
https://doi.org/10.1051/e3sconf/202459201011/pdf
Primary Topic
Solid State Laser Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of thermo-optical effects in a nonlinear ZnGeP

Springer Link (Chiba Institute of Technology)
Solid State Laser Technologies
article

Investigation of thermo-optical effects in a nonlinear ZnGeP

article en

Abstract

\nThis work is dedicated to investigating the thermo-optical effects in a nonlinear ZnGeP2 crystal during parametric generation. The stable regime of the laser resonator was determined. It was found that for a resonator length of 43 mm, a stable regime was observed for all focal lengths of the thermal lens induced in the crystal. However, increasing the resonator length to 183 mm, the stability zone of the cavity no longer extends to the entire range of focal lengths of the induced thermal lens. Thus, the resonator becomes unstable for focal lengths of the induced thermal lens f ≤ 150 mm, which leads to high intracavity losses and is an undesirable operating mode of the cavity. Therefore, the experimental work has shown that when creating systems based on parametric generators with ZnGeP2 crystals, it is essential to consider the effect of the induced thermal lens and perform calculations of the cavity stability.\n

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 69%
Solid State Laser Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.