Power System Fault Recovery Considering Frequency Deviation Under Large-Scale Wind Power Access

[Objective] This study addresses the challenges posed by the increasing integration of high proportions of renewable energy on the safe and stable operation of power systems. The objective is to enhance reserve capacity during fault recovery process, thereby ensuring system frequency stability. A novel fault recovery model, incorporating frequency deviation under large-scale wind power integration, is proposed to optimize this process. [Methods] First, a power system frequency response model that incorporates large-scale wind power integration was developed. The frequency deviation was derived using the Laplace final value theorem, and power fluctuations were calculated. Second, to maximize the incorporation of generator regulation capacity, the minimum values of the power fluctuations, generator output boundary, and ramp rate were considered to determine the maximum adjustable reserve capacity of each unit. This ensures sufficient reserve capacity during fault recovery to address wind power fluctuations. Third, to address the multi-objective nonlinear nature of the fault recovery model, piecewise linearization and weighting methods were employed to solve the multi-objective function with load loss, generator operation cost, and reserve cost as the objectives. [Results] The model was validated using an IEEE 39-bus system. A comparison among conventional fault recovery (without considering frequency deviation), reserve recovery (without considering frequency deviation), and reserve recovery (considering frequency deviation) demonstrates that the proposed reserve recovery model enables more efficient reserve capacity allocation during fault recovery. Therefore, it ensures that the system frequency deviation remains within ± 0.2 Hz. Additionally, the model reduces system load loss by approximately 24.63% and the total cost by approximately 36.62% compared with traditional methods. [Conclusions] The proposed model significantly suppresses the frequency fluctuation before and after a fault, ensuring stable operation of the system frequency while achieving optimal economic benefits and reducing fault load loss.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
DOI
https://doi.org/10.12204/j.issn.1000-7229.2025.05.014
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power System Fault Recovery Considering Frequency Deviation Under Large-Scale Wind Power Access

SHILAP Revista de lepidopterología
Wind Turbine Control Systems
article

Power System Fault Recovery Considering Frequency Deviation Under Large-Scale Wind Power Access

article en

Abstract

[Objective] This study addresses the challenges posed by the increasing integration of high proportions of renewable energy on the safe and stable operation of power systems. The objective is to enhance reserve capacity during fault recovery process, thereby ensuring system frequency stability. A novel fault recovery model, incorporating frequency deviation under large-scale wind power integration, is proposed to optimize this process. [Methods] First, a power system frequency response model that incorporates large-scale wind power integration was developed. The frequency deviation was derived using the Laplace final value theorem, and power fluctuations were calculated. Second, to maximize the incorporation of generator regulation capacity, the minimum values of the power fluctuations, generator output boundary, and ramp rate were considered to determine the maximum adjustable reserve capacity of each unit. This ensures sufficient reserve capacity during fault recovery to address wind power fluctuations. Third, to address the multi-objective nonlinear nature of the fault recovery model, piecewise linearization and weighting methods were employed to solve the multi-objective function with load loss, generator operation cost, and reserve cost as the objectives. [Results] The model was validated using an IEEE 39-bus system. A comparison among conventional fault recovery (without considering frequency deviation), reserve recovery (without considering frequency deviation), and reserve recovery (considering frequency deviation) demonstrates that the proposed reserve recovery model enables more efficient reserve capacity allocation during fault recovery. Therefore, it ensures that the system frequency deviation remains within ± 0.2 Hz. Additionally, the model reduces system load loss by approximately 24.63% and the total cost by approximately 36.62% compared with traditional methods. [Conclusions] The proposed model significantly suppresses the frequency fluctuation before and after a fault, ensuring stable operation of the system frequency while achieving optimal economic benefits and reducing fault load loss.

SHILAP Revista de lepidopterología
State Grid Corporation of China (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 57%
Wind Turbine Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.