A Practical Implementation of RESTful API and WebSocket Protocol for Power Efficiency Monitoring: A Case Study at Muhammadiyah Orphanage

Power efficiency needs to be monitored to avoid adverse effects on electricity users, particularly those with significant inductive loads. However, current monitoring devices are limited in their ability to continuously record data and represent outputs effectively. This study designs an IoT-based reactive power and power factor monitoring system using a RESTful API for electrical equipment at a Muhammadiyah orphanage. The proposed system utilizes the PZEM-004T as the power sensor, the ESP32 microprocessor as the data processing unit, and a web server as the interface for settings and data visualization. Measurement records for reactive power and power factor can be stored in internal data storage. Additionally, remote monitoring can be conducted via WebSocket protocol and the Telegram application. The system has been tested by comparing reactive power, power factor, kWh, and cost with a standard power meter. The results demonstrate that the sensor exhibits an error of 9.02% in current measurement and 1.106% in active power measurement, with an average delay of 0.137 seconds via WebSocket-based server and 1.359 seconds using Telegram application.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-09-18
DOI
https://doi.org/10.1051/e3sconf/202457001005/pdf
Primary Topic
IoT-based Control Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Practical Implementation of RESTful API and WebSocket Protocol for Power Efficiency Monitoring: A Case Study at Muhammadiyah Orphanage

Springer Link (Chiba Institute of Technology)
IoT-based Control Systems
article

A Practical Implementation of RESTful API and WebSocket Protocol for Power Efficiency Monitoring: A Case Study at Muhammadiyah Orphanage

article en

Abstract

Power efficiency needs to be monitored to avoid adverse effects on electricity users, particularly those with significant inductive loads. However, current monitoring devices are limited in their ability to continuously record data and represent outputs effectively. This study designs an IoT-based reactive power and power factor monitoring system using a RESTful API for electrical equipment at a Muhammadiyah orphanage. The proposed system utilizes the PZEM-004T as the power sensor, the ESP32 microprocessor as the data processing unit, and a web server as the interface for settings and data visualization. Measurement records for reactive power and power factor can be stored in internal data storage. Additionally, remote monitoring can be conducted via WebSocket protocol and the Telegram application. The system has been tested by comparing reactive power, power factor, kWh, and cost with a standard power meter. The results demonstrate that the sensor exhibits an error of 9.02% in current measurement and 1.106% in active power measurement, with an average delay of 0.137 seconds via WebSocket-based server and 1.359 seconds using Telegram application.

Springer Link (Chiba Institute of Technology)
Universitas Muhammadiyah Yogyakarta
Affordable and clean energy
Openalex Percentile: Top 63%
IoT-based Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.