MIP-Chip: IntegratedMicrofluidic Plasma Separationand Redox-Enhanced Molecularly Imprinted Polymer Succinate Sensorfor Whole Blood Metabolite Analysis

The precise quantification of metabolites in bodily fluids is essential for advancing digital health monitoring and clinical diagnostics. Among these fluids, whole blood stands out as a valuable source of predictive metabolite biomarkers, providing critical insights into disease diagnosis and progression. However, traditional blood testing methods often require expensive instrumentation and specialized training, primarily due to the need for plasma extraction to remove interfering blood cells. This study addresses these limitations by introducing a novel, sensitive, rapid, reagent-free, and cost-effective capillary microfluidic-integrated molecularly imprinted polymer (MIP) sensor (MIP-Chip) designed for metabolite detection in whole blood. The MIP-Chip integrates two key components: (1) a highly efficient plasma separation module capable of extracting plasma from whole blood (∼95% efficiency) without requiring sample pretreatment or external active forces and (2) an electrochemical MIP sensor employing an ultrasensitive electrode with on-electrode Prussian Blue nanoparticles (PB NPs) as embedded redox probes for sensitive and specific metabolite detection in the extracted plasma. Using this platform, we successfully quantified succinate, a critical metabolite, across a wide linear concentration range (50 nM–250 μM) with a limit of detection of 5 nM. The device processed 120 μL of whole blood, delivering 8 μL of plasma, and completed the entire workflow-from sample introduction to biomarker detection within 25 min. The MIP-Chip demonstrated exceptional performance, including self-powered assay automation, high specificity for succinate quantification in whole blood, excellent reproducibility, and long-term stability of the MIP-based sensor. These features establish the MIP-Chip as a powerful analytical platform for point-of-care diagnostics, offering a significant step forward in clinical metabolite detection and digital health monitoring.

Publication Details

Journal
Figshare
Published
2025-03-27
DOI
https://doi.org/10.1021/acssensors.5c00355.s001
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MIP-Chip: IntegratedMicrofluidic Plasma Separationand Redox-Enhanced Molecularly Imprinted Polymer Succinate Sensorfor Whole Blood Metabolite Analysis

Figshare
Analytical chemistry methods development
article

MIP-Chip: IntegratedMicrofluidic Plasma Separationand Redox-Enhanced Molecularly Imprinted Polymer Succinate Sensorfor Whole Blood Metabolite Analysis

article en

Abstract

The precise quantification of metabolites in bodily fluids is essential for advancing digital health monitoring and clinical diagnostics. Among these fluids, whole blood stands out as a valuable source of predictive metabolite biomarkers, providing critical insights into disease diagnosis and progression. However, traditional blood testing methods often require expensive instrumentation and specialized training, primarily due to the need for plasma extraction to remove interfering blood cells. This study addresses these limitations by introducing a novel, sensitive, rapid, reagent-free, and cost-effective capillary microfluidic-integrated molecularly imprinted polymer (MIP) sensor (MIP-Chip) designed for metabolite detection in whole blood. The MIP-Chip integrates two key components: (1) a highly efficient plasma separation module capable of extracting plasma from whole blood (∼95% efficiency) without requiring sample pretreatment or external active forces and (2) an electrochemical MIP sensor employing an ultrasensitive electrode with on-electrode Prussian Blue nanoparticles (PB NPs) as embedded redox probes for sensitive and specific metabolite detection in the extracted plasma. Using this platform, we successfully quantified succinate, a critical metabolite, across a wide linear concentration range (50 nM–250 μM) with a limit of detection of 5 nM. The device processed 120 μL of whole blood, delivering 8 μL of plasma, and completed the entire workflow-from sample introduction to biomarker detection within 25 min. The MIP-Chip demonstrated exceptional performance, including self-powered assay automation, high specificity for succinate quantification in whole blood, excellent reproducibility, and long-term stability of the MIP-based sensor. These features establish the MIP-Chip as a powerful analytical platform for point-of-care diagnostics, offering a significant step forward in clinical metabolite detection and digital health monitoring.

Figshare
Openalex Percentile: Top 55%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

MIP-Chip: IntegratedMicrofluidic Plasma Separationand Redox-Enhanced Molecularly Imprinted Polymer Succinate Sensorfor Whole Blood Metabolite Analysis · Figshare (2025) | TGRS Research Map | TGRS