Dynamic Monitoring and Ventilation Parameter Coupling Optimization for PM

This study systematically investigates ventilation-coupled PM2.5 dispersion dynamics in healthcare settings through multi-parametric monitoring of moxibustion-generated particulate pollution. Experimental results demonstrate height-dependent nonlinear interactions between exhaust airflow rates and PM2.5 concentrations, where reducing exhaust hood installation heights to ≤20 cm enhanced particulate control efficiency by 4.3–5.2-fold compared to conventional 30 cm configurations, validating the critical need for geometric optimisation. Hybrid ventilation modes induced severe airflow interference, elevating PM2.5 mass concentrations by 146.8% relative to standalone mechanical exhaust, with window-integrated operations exhibiting the most pronounced instability (58% higher concentration fluctuations than closed-environment scenarios). The developed “closed-environment + low-height mechanical exhaust (115 m3/h)” protocol achieved dual optimisation of control efficacy and operational stability, maintaining patient breathing zone concentrations below 50 μg/m3 across all test cycles. These findings provide empirical validation for revising dynamic pollution source monitoring thresholds in the Indoor Air Quality Standard (GB/T 18883-2022), particularly addressing real-time control requirements for medical spaces with intermittent high-emission activities.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-05-22
DOI
https://doi.org/10.1051/e3sconf/202563001012/pdf
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Monitoring and Ventilation Parameter Coupling Optimization for PM

Springer Link (Chiba Institute of Technology)
Infection Control and Ventilation
article

Dynamic Monitoring and Ventilation Parameter Coupling Optimization for PM

article en

Abstract

This study systematically investigates ventilation-coupled PM2.5 dispersion dynamics in healthcare settings through multi-parametric monitoring of moxibustion-generated particulate pollution. Experimental results demonstrate height-dependent nonlinear interactions between exhaust airflow rates and PM2.5 concentrations, where reducing exhaust hood installation heights to ≤20 cm enhanced particulate control efficiency by 4.3–5.2-fold compared to conventional 30 cm configurations, validating the critical need for geometric optimisation. Hybrid ventilation modes induced severe airflow interference, elevating PM2.5 mass concentrations by 146.8% relative to standalone mechanical exhaust, with window-integrated operations exhibiting the most pronounced instability (58% higher concentration fluctuations than closed-environment scenarios). The developed “closed-environment + low-height mechanical exhaust (115 m3/h)” protocol achieved dual optimisation of control efficacy and operational stability, maintaining patient breathing zone concentrations below 50 μg/m3 across all test cycles. These findings provide empirical validation for revising dynamic pollution source monitoring thresholds in the Indoor Air Quality Standard (GB/T 18883-2022), particularly addressing real-time control requirements for medical spaces with intermittent high-emission activities.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 39%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.