Accuracy of acetabular cup positioning in robotic-assisted total hip arthroplasty: a CT-based evaluation

Introduction: Robot-assisted instrumentation during total hip arthroplasty (THA) has the potential to improve acetabular cup positioning. This study aimed to evaluate the precision of robotic-arm-assisted THA (rTHA) and assess whether the system can provide accurate cup positioning comparable to conventional THA (cTHA). Methods: A single-center prospective cohort study consisting of 151 patients who underwent THA (108 rTHA and 43 cTHA). The robotically assisted system was used to match the postoperative computed tomography (CT) image of the pelvis with the planned and intraoperative anatomical landmarks. The cTHA cohort underwent hip replacement using the standard manual procedure, with acetabular component locations assessed during and after surgery. Results: The rTHA cohort was significantly younger, but no other significant differences were found between the two cohorts in preoperative baseline data. In rTHA cohort, the planned inclination (40.0 ± 0.3°) closely matched the intraoperative (40.2 ± 2.7°; p = 0.54) and postoperative (40.7 ± 4.0°; p = 0.07) measurements. However, anteversion showed a significant increase from planned (19.4 ± 1.5°) to postoperative CT scan (28.7 ± 7.0°; p < 0.001). There was evidence of proportional bias in the measurements (p < 0.001). In the cTHA cohort, the mean inclination (43.1 ± 5.1°) did not show any significant change between the preoperative plans and postoperative assessments (p = 0.12); however, there was a remarkable change in the mean anteversion (17.6 ± 6.4°) between postoperative measurements and the preoperative plans (p < 0.001). The average anteversion in the preoperative plans did not differ remarkably between the rTHA and cTHA cohorts. However, the average inclination was substantially different between the two cohorts (p < 0.001). Both groups had no significant differences in the proportion of cups outside the referenced safe zones. Conclusion: The results suggest that while robotic-assisted guidance ensures consistent cup inclination, there may be more variability in achieving the planned anteversion, which warrants further investigation into the factors influencing postoperative changes in acetabular orientation.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-12-20
DOI
https://doi.org/10.1051/sicotj/2024057/pdf
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of acetabular cup positioning in robotic-assisted total hip arthroplasty: a CT-based evaluation

Springer Link (Chiba Institute of Technology)
Orthopaedic implants and arthroplasty
article

Accuracy of acetabular cup positioning in robotic-assisted total hip arthroplasty: a CT-based evaluation

article en

Abstract

Introduction: Robot-assisted instrumentation during total hip arthroplasty (THA) has the potential to improve acetabular cup positioning. This study aimed to evaluate the precision of robotic-arm-assisted THA (rTHA) and assess whether the system can provide accurate cup positioning comparable to conventional THA (cTHA). Methods: A single-center prospective cohort study consisting of 151 patients who underwent THA (108 rTHA and 43 cTHA). The robotically assisted system was used to match the postoperative computed tomography (CT) image of the pelvis with the planned and intraoperative anatomical landmarks. The cTHA cohort underwent hip replacement using the standard manual procedure, with acetabular component locations assessed during and after surgery. Results: The rTHA cohort was significantly younger, but no other significant differences were found between the two cohorts in preoperative baseline data. In rTHA cohort, the planned inclination (40.0 ± 0.3°) closely matched the intraoperative (40.2 ± 2.7°; p = 0.54) and postoperative (40.7 ± 4.0°; p = 0.07) measurements. However, anteversion showed a significant increase from planned (19.4 ± 1.5°) to postoperative CT scan (28.7 ± 7.0°; p < 0.001). There was evidence of proportional bias in the measurements (p < 0.001). In the cTHA cohort, the mean inclination (43.1 ± 5.1°) did not show any significant change between the preoperative plans and postoperative assessments (p = 0.12); however, there was a remarkable change in the mean anteversion (17.6 ± 6.4°) between postoperative measurements and the preoperative plans (p < 0.001). The average anteversion in the preoperative plans did not differ remarkably between the rTHA and cTHA cohorts. However, the average inclination was substantially different between the two cohorts (p < 0.001). Both groups had no significant differences in the proportion of cups outside the referenced safe zones. Conclusion: The results suggest that while robotic-assisted guidance ensures consistent cup inclination, there may be more variability in achieving the planned anteversion, which warrants further investigation into the factors influencing postoperative changes in acetabular orientation.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 49%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy of acetabular cup positioning in robotic-assisted total hip arthroplasty: a CT-based evaluation · Springer Link (Chiba Institute of Technology) (2024) | TGRS Research Map | TGRS