Functional redundancy of air exchange processes in technological premises for poultry keeping

The article focuses on the problem associated with emergency power outages at poultry farms. Poultry farming is one of the key branches of agriculture underlying the implementation of the country’s food security doctrine. The trouble-free operation of the technological equipment of poultry workshops is an important and essential condition for improving the productivity and health of poultry. The article presents a method for calculating the multiplicity of air exchange, which makes it possible to determine the optimal parameters of natural ventilation to stabilize microclimatic conditions in a poultry shop in the event of an emergency in the power supply system. The analysis of infrared thermography of the poultry housing confirms the presence of thermally stressed zones and the unevenness of their distribution, which is a prerequisite for creating a model for leveling temperature fields to a physiologically comfortable level for poultry. The article proposes to consider the issue of introducing refrigeration units into the production cycle as a method of solving the issue of livestock safety if it is necessary to transfer the ventilation system to a free-convection mode. The arguments put forward in the article are focused on the impossibility of the bird’s vital activity during the transitional and warm periods, even with a short-term shutdown of the ventilation system. The creation of a temperature difference will provide a backup air exchange for the period of repair work. The analysis of electricity consumption at a poultry enterprise by month allows us to put forward a proposal to redistribute part of it to the cold storage process. The preliminary calculations carried out confirm the sufficiency of the part of the electricity allocated for the implementation of air-conditioned air exchange, with the “tunnel” type ventilation used.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-10-09
DOI
https://doi.org/10.1051/bioconf/202413007006/pdf
Primary Topic
Advanced Materials and Semiconductor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Functional redundancy of air exchange processes in technological premises for poultry keeping

Springer Link (Chiba Institute of Technology)
Advanced Materials and Semiconductor Technologies
article

Functional redundancy of air exchange processes in technological premises for poultry keeping

article en

Abstract

The article focuses on the problem associated with emergency power outages at poultry farms. Poultry farming is one of the key branches of agriculture underlying the implementation of the country’s food security doctrine. The trouble-free operation of the technological equipment of poultry workshops is an important and essential condition for improving the productivity and health of poultry. The article presents a method for calculating the multiplicity of air exchange, which makes it possible to determine the optimal parameters of natural ventilation to stabilize microclimatic conditions in a poultry shop in the event of an emergency in the power supply system. The analysis of infrared thermography of the poultry housing confirms the presence of thermally stressed zones and the unevenness of their distribution, which is a prerequisite for creating a model for leveling temperature fields to a physiologically comfortable level for poultry. The article proposes to consider the issue of introducing refrigeration units into the production cycle as a method of solving the issue of livestock safety if it is necessary to transfer the ventilation system to a free-convection mode. The arguments put forward in the article are focused on the impossibility of the bird’s vital activity during the transitional and warm periods, even with a short-term shutdown of the ventilation system. The creation of a temperature difference will provide a backup air exchange for the period of repair work. The analysis of electricity consumption at a poultry enterprise by month allows us to put forward a proposal to redistribute part of it to the cold storage process. The preliminary calculations carried out confirm the sufficiency of the part of the electricity allocated for the implementation of air-conditioned air exchange, with the “tunnel” type ventilation used.

Springer Link (Chiba Institute of Technology)
Zero hunger
Openalex Percentile: Top 78%
Advanced Materials and Semiconductor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.