Application of Combined Fission Matrix to Plate-type Research Reactor

\nThe Combined Fission Matrix (CFM) method entails the instantaneous estimation of the entire system's fission matrix by amalgamating fission matrices from a pre-existing database. This approach allows for the rapid and accurate determination of the effective multiplication factor (keff) and the distribution of fission rates across the reactor system. This work applies the CFM method to the Japan Research Reactor-3 (JRR-3M), a water-cooled plate-type reactor. The CFM method demonstrates a high level of agreement with Monte Carlo (MC) simulation results, completing calculations within a minute. In the two cases of 'All Absorbers In' and 'All Absorbers Out', this method achieved a low root-mean-square (RMS) error of only 0.4% and 1% , respectively, with keff-error of 44 pcm and 24 pcm .\n

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-10-15
DOI
https://doi.org/10.1051/epjconf/202430213005/pdf
Primary Topic
Nuclear reactor physics and engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Combined Fission Matrix to Plate-type Research Reactor

Springer Link (Chiba Institute of Technology)
Nuclear reactor physics and engineering
article

Application of Combined Fission Matrix to Plate-type Research Reactor

article en

Abstract

\nThe Combined Fission Matrix (CFM) method entails the instantaneous estimation of the entire system's fission matrix by amalgamating fission matrices from a pre-existing database. This approach allows for the rapid and accurate determination of the effective multiplication factor (keff) and the distribution of fission rates across the reactor system. This work applies the CFM method to the Japan Research Reactor-3 (JRR-3M), a water-cooled plate-type reactor. The CFM method demonstrates a high level of agreement with Monte Carlo (MC) simulation results, completing calculations within a minute. In the two cases of 'All Absorbers In' and 'All Absorbers Out', this method achieved a low root-mean-square (RMS) error of only 0.4% and 1% , respectively, with keff-error of 44 pcm and 24 pcm .\n

Springer Link (Chiba Institute of Technology)
Clean water and sanitation
Openalex Percentile: Top 41%
Nuclear reactor physics and engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.