High-PerformanceOxide Crystal BaTeW<sub>2</sub>O<sub>9</sub> X‑ray Detectorwith High Stability, Low DetectionLimit, and Ultralow Dark Current Drift

X-ray detection materials and devices have received widespread attention due to their irreplaceable role in the medical, industrial, and military fields. In this paper, BaTeW<sub>2</sub>O<sub>9</sub> (BTW) crystal containing lone pairs of electrons with large atomic numbers and high density is reported as a new type of oxide crystal X-ray detection material. The anisotropic X-ray detection performance of the BTW single crystal (SC) is systematically studied. At 120 keV hard X-ray photon energy, the BTW SC X-ray detectors along the crystallographic <i>a</i>-, <i>b</i>-, and <i>c</i>-axes directions achieved high sensitivities of 371, 404, and 368 μC Gy<sub>air</sub><sup>–1</sup> cm<sup>–2</sup> respectively. More importantly, no dark current drift phenomenon was observed in the BTW SC X-ray detectors. The dark current drifts along the crystallographic <i>a</i>-, <i>b</i>-, and <i>c</i>-axes directions are as low as 7.81 × 10<sup>–9</sup>, 8.61 × 10<sup>–9</sup>, and 7.71 × 10<sup>–9</sup> nA cm<sup>–1</sup> s<sup>–1</sup> V<sup>–1</sup>, respectively. In addition, the BTW SC X-ray detector has an ultralow detection limit of 21.9 nGy<sub>air</sub> s<sup>–1</sup>. Our research provides a new X-ray detection material with potential application value and a new material design strategy for the field of radiation detection.

Publication Details

Journal
Figshare
Published
2025-01-28
DOI
https://doi.org/10.1021/acsami.4c17909.s001
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-PerformanceOxide Crystal BaTeW2O9 X‑ray Detectorwith High Stability, Low DetectionLimit, and Ultralow Dark Current Drift

Figshare
Radiation Detection and Scintillator Technologies
article

High-PerformanceOxide Crystal BaTeW2O9 X‑ray Detectorwith High Stability, Low DetectionLimit, and Ultralow Dark Current Drift

article en

Abstract

X-ray detection materials and devices have received widespread attention due to their irreplaceable role in the medical, industrial, and military fields. In this paper, BaTeW<sub>2</sub>O<sub>9</sub> (BTW) crystal containing lone pairs of electrons with large atomic numbers and high density is reported as a new type of oxide crystal X-ray detection material. The anisotropic X-ray detection performance of the BTW single crystal (SC) is systematically studied. At 120 keV hard X-ray photon energy, the BTW SC X-ray detectors along the crystallographic <i>a</i>-, <i>b</i>-, and <i>c</i>-axes directions achieved high sensitivities of 371, 404, and 368 μC Gy<sub>air</sub><sup>–1</sup> cm<sup>–2</sup> respectively. More importantly, no dark current drift phenomenon was observed in the BTW SC X-ray detectors. The dark current drifts along the crystallographic <i>a</i>-, <i>b</i>-, and <i>c</i>-axes directions are as low as 7.81 × 10<sup>–9</sup>, 8.61 × 10<sup>–9</sup>, and 7.71 × 10<sup>–9</sup> nA cm<sup>–1</sup> s<sup>–1</sup> V<sup>–1</sup>, respectively. In addition, the BTW SC X-ray detector has an ultralow detection limit of 21.9 nGy<sub>air</sub> s<sup>–1</sup>. Our research provides a new X-ray detection material with potential application value and a new material design strategy for the field of radiation detection.

Figshare
Openalex Percentile: Top 46%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-PerformanceOxide Crystal BaTeW<sub>2</sub>O<sub>9</sub> X‑ray Detectorwith High Stability, Low DetectionLimit, and Ultralow Dark Current Drift · Figshare (2025) | TGRS Research Map | TGRS