Waveguide-Based\nMicrowave Nitric Oxide Sensor for\nCOVID-19 Screening: Mass Transfer Modulation Effect on Hollow Confined\nWO<sub>3</sub> Structures

Serious\nacute respiratory syndrome coronavirus-2 (SARS-CoV-2)\nposes\na tremendous threat to global public health. Recently, the Food and\nDrug Administration approved the emergency use of volatile organic\ncomponents as detection biomarkers for COVID-19, ushering in a new\nera of portable, simple, and rapid epidemiological screening based\non breath diagnosis. Nitric oxide (NO) is an important biomarker indicating\nthe degree of inflammation in the respiratory tract. In this study,\na hollow multishelled structured WO<sub>3</sub> (HoMSs-WO<sub>3</sub>)-based waveguide microwave gas sensor (MGS) was fabricated to detect\ntrace levels of NO in exhaled breath for the preliminary diagnosis\nof COVID-19. The sensor showed excellent reusability and selectivity\nand efficiently detected NO in the 10–100 ppb, with a sensitivity\nof 39.27 dB/ppm and a detection limit of 2.52 ppb. In addition, a\nsound correlation was observed in the measurement results between\nthe MGS and the Sunvou detector for detecting NO from the exhaled\nbreath of clinical COVID-19 patients. The difference between the two\nmeasurements was within 1.96 standard bias, and the consistency range\nwas −12 to 17 ppb, thus fully demonstrating the significant\npotential of the sensor in COVID-19 screening.

Publication Details

Journal
Figshare
Published
2024-10-23
DOI
https://doi.org/10.1021/acssensors.4c01889.s001
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Waveguide-Based\nMicrowave Nitric Oxide Sensor for\nCOVID-19 Screening: Mass Transfer Modulation Effect on Hollow Confined\nWO3 Structures

Figshare
Advanced Chemical Sensor Technologies
article

Waveguide-Based\nMicrowave Nitric Oxide Sensor for\nCOVID-19 Screening: Mass Transfer Modulation Effect on Hollow Confined\nWO3 Structures

article en

Abstract

Serious\nacute respiratory syndrome coronavirus-2 (SARS-CoV-2)\nposes\na tremendous threat to global public health. Recently, the Food and\nDrug Administration approved the emergency use of volatile organic\ncomponents as detection biomarkers for COVID-19, ushering in a new\nera of portable, simple, and rapid epidemiological screening based\non breath diagnosis. Nitric oxide (NO) is an important biomarker indicating\nthe degree of inflammation in the respiratory tract. In this study,\na hollow multishelled structured WO<sub>3</sub> (HoMSs-WO<sub>3</sub>)-based waveguide microwave gas sensor (MGS) was fabricated to detect\ntrace levels of NO in exhaled breath for the preliminary diagnosis\nof COVID-19. The sensor showed excellent reusability and selectivity\nand efficiently detected NO in the 10–100 ppb, with a sensitivity\nof 39.27 dB/ppm and a detection limit of 2.52 ppb. In addition, a\nsound correlation was observed in the measurement results between\nthe MGS and the Sunvou detector for detecting NO from the exhaled\nbreath of clinical COVID-19 patients. The difference between the two\nmeasurements was within 1.96 standard bias, and the consistency range\nwas −12 to 17 ppb, thus fully demonstrating the significant\npotential of the sensor in COVID-19 screening.

Figshare
Good health and well-being
Openalex Percentile: Top 71%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.