Direct CoronaCharging: A New Strategy for EnhancingSensitivity and Stability in Charged Aerosol Detection

The charged aerosol detector (CAD) is widely used for detecting nonvolatile compounds without UV absorption due to its high sensitivity, stability, and consistent response. However, the traditional plasma collision charging mode (PCCM) suffers from issues such as sample dilution, gas flow back-mixing, and disturbances, which reduce sensitivity and repeatability. To address these limitations, this study introduces the direct corona charging mode (DCCM), which eliminates the charging gas route by using a high-voltage corona needle to directly charge the dried aerosol. This approach avoids mixing collisions, simplifies the instrument structure, and reduces nitrogen consumption. Comparative analyses using samples like caffeine demonstrated that DCCM significantly improves sensitivity and stability over PCCM. The response under DCCM fits a quadratic curve with a correlation coefficient above 0.99 across 3 orders of magnitude. Direct injection of 22 analytes showed that DCCM achieved a peak area relative standard deviation below 10%, with better response consistency than PCCM. Gradient analysis of complex samples further confirmed DCCM’s superior repeatability and sensitivity. Real-sample analysis highlighted DCCM-CAD’s practical potential. In summary, DCCM enhances CAD performance, reduces costs, and simplifies design, paving the way for more efficient and reliable commercial CAD systems.

Publication Details

Journal
Figshare
Published
2025-03-28
DOI
https://doi.org/10.1021/acs.analchem.4c05557.s001
Primary Topic
Atmospheric chemistry and aerosols
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct CoronaCharging: A New Strategy for EnhancingSensitivity and Stability in Charged Aerosol Detection

Figshare
Atmospheric chemistry and aerosols
article

Direct CoronaCharging: A New Strategy for EnhancingSensitivity and Stability in Charged Aerosol Detection

article en

Abstract

The charged aerosol detector (CAD) is widely used for detecting nonvolatile compounds without UV absorption due to its high sensitivity, stability, and consistent response. However, the traditional plasma collision charging mode (PCCM) suffers from issues such as sample dilution, gas flow back-mixing, and disturbances, which reduce sensitivity and repeatability. To address these limitations, this study introduces the direct corona charging mode (DCCM), which eliminates the charging gas route by using a high-voltage corona needle to directly charge the dried aerosol. This approach avoids mixing collisions, simplifies the instrument structure, and reduces nitrogen consumption. Comparative analyses using samples like caffeine demonstrated that DCCM significantly improves sensitivity and stability over PCCM. The response under DCCM fits a quadratic curve with a correlation coefficient above 0.99 across 3 orders of magnitude. Direct injection of 22 analytes showed that DCCM achieved a peak area relative standard deviation below 10%, with better response consistency than PCCM. Gradient analysis of complex samples further confirmed DCCM’s superior repeatability and sensitivity. Real-sample analysis highlighted DCCM-CAD’s practical potential. In summary, DCCM enhances CAD performance, reduces costs, and simplifies design, paving the way for more efficient and reliable commercial CAD systems.

Figshare
Openalex Percentile: Top 53%
Atmospheric chemistry and aerosols
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.