Ultracompactand Highly Sensitive Atomic MagnetometerArray via a Polarization Volume Grating-Based Waveguide Structure

Ultraweak magnetic field measurement, as one of the quantum precision measurement techniques, holds important significance in the forefront of explorations in physics and advanced medical technologies. The atomic magnetometer, serving as a typical instrument for measuring extremely weak magnetic fields, utilizes the Larmor precession frequency of electrons in alkali metal atoms to quantify magnetic field magnitudes at subfemtotesla levels. Additionally, atomic magnetometers boast advantages such as high sensitivity, miniaturization and high spatial resolution. Hence, arrays of atomic magnetometer sensors have become a reliable solution for measuring ultraweak magnetic fields in spatial dimensions. This paper proposes an ultracompact and highly sensitive atomic magnetometer array integrated structure via a highly stable polarization volume grating (PVG)-based waveguide structure for beam splitting. Instead of the traditional four polarizing beam splitters and polarizors, the structure integrates parallel beam splitting and polarization conversion functions using PVGs, which are then incorporated into an ultracompact atomic magnetometer array. This integration enables high sensitivity magnetic field measurements in four channels. The light separated by the structure exhibits power fluctuations along a single polarization axis below 0.2% during a 30 min period. The overall volume of the proposed integrated structure is approximately 0.6 cm<sup>3</sup>, representing at least an order of magnitude reduction compared to other spatial optical atomic magnetometer array structures. The final validation demonstrates the system can measure magnetic fields on the order of femtotesla, with an average sensitivity of 16.1 fT/Hz<sup>1/2</sup>. This approach holds significant potential for applications in quantum precision sensing, high resolution medical imaging, and biological science exploration.

Publication Details

Journal
Figshare
Published
2025-02-20
DOI
https://doi.org/10.1021/acsphotonics.4c02361.s001
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultracompactand Highly Sensitive Atomic MagnetometerArray via a Polarization Volume Grating-Based Waveguide Structure

Figshare
Atomic and Subatomic Physics Research
article

Ultracompactand Highly Sensitive Atomic MagnetometerArray via a Polarization Volume Grating-Based Waveguide Structure

article en

Abstract

Ultraweak magnetic field measurement, as one of the quantum precision measurement techniques, holds important significance in the forefront of explorations in physics and advanced medical technologies. The atomic magnetometer, serving as a typical instrument for measuring extremely weak magnetic fields, utilizes the Larmor precession frequency of electrons in alkali metal atoms to quantify magnetic field magnitudes at subfemtotesla levels. Additionally, atomic magnetometers boast advantages such as high sensitivity, miniaturization and high spatial resolution. Hence, arrays of atomic magnetometer sensors have become a reliable solution for measuring ultraweak magnetic fields in spatial dimensions. This paper proposes an ultracompact and highly sensitive atomic magnetometer array integrated structure via a highly stable polarization volume grating (PVG)-based waveguide structure for beam splitting. Instead of the traditional four polarizing beam splitters and polarizors, the structure integrates parallel beam splitting and polarization conversion functions using PVGs, which are then incorporated into an ultracompact atomic magnetometer array. This integration enables high sensitivity magnetic field measurements in four channels. The light separated by the structure exhibits power fluctuations along a single polarization axis below 0.2% during a 30 min period. The overall volume of the proposed integrated structure is approximately 0.6 cm<sup>3</sup>, representing at least an order of magnitude reduction compared to other spatial optical atomic magnetometer array structures. The final validation demonstrates the system can measure magnetic fields on the order of femtotesla, with an average sensitivity of 16.1 fT/Hz<sup>1/2</sup>. This approach holds significant potential for applications in quantum precision sensing, high resolution medical imaging, and biological science exploration.

Figshare
Openalex Percentile: Top 63%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.