Dual RatiometricFluorescence Sensors Based on ChiralCarbon Dots for the Sensitive and Specific Detection of Arginine

Arginine (Arg) is involved in tissue metabolism and regulates the immune function; thereby, achieving the detection of Arg is crucial for early diagnosis and treatment of diseases. Herein, dual ratiometric fluorescence sensors were prepared with the blue emission of levorotatory/dextrorotatory carbon dots (CDs) and the red emission of porphyrin (L/D-CDs-PP) for the sensitive and portable detection of Arg. Interestingly, L-CDs-PP and D-CDs-PP displayed not only the dual emission peaks at 493 and 650 nm but also different response modes to Arg; thus, they could serve as dual ratiometric fluorescence sensors to achieve the accurate and reliable detection of Arg, with the detection limit of 23.87 μM for L-CDs-PP and 2.39 μM for D-CDs-PP. Importantly, the solid-state sensors successfully achieved dual-mode visual and portable detection of Arg with the support of a smartphone platform. In addition, L-CDs-PP and D-CDs-PP exhibited excellent biocompatibility and cell imaging capabilities, and they could achieve the detection of Arg in cells and biological samples of urine and rat plasma. Therefore, the dual ratiometric fluorescence sensors exhibited broad application prospects in the fields of analytical sensing, biological imaging, and medical diagnosis.

Publication Details

Journal
Figshare
Published
2025-01-15
DOI
https://doi.org/10.1021/acs.analchem.4c06405.s001
Primary Topic
Carbon and Quantum Dots Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual RatiometricFluorescence Sensors Based on ChiralCarbon Dots for the Sensitive and Specific Detection of Arginine

Figshare
Carbon and Quantum Dots Applications
article

Dual RatiometricFluorescence Sensors Based on ChiralCarbon Dots for the Sensitive and Specific Detection of Arginine

article en

Abstract

Arginine (Arg) is involved in tissue metabolism and regulates the immune function; thereby, achieving the detection of Arg is crucial for early diagnosis and treatment of diseases. Herein, dual ratiometric fluorescence sensors were prepared with the blue emission of levorotatory/dextrorotatory carbon dots (CDs) and the red emission of porphyrin (L/D-CDs-PP) for the sensitive and portable detection of Arg. Interestingly, L-CDs-PP and D-CDs-PP displayed not only the dual emission peaks at 493 and 650 nm but also different response modes to Arg; thus, they could serve as dual ratiometric fluorescence sensors to achieve the accurate and reliable detection of Arg, with the detection limit of 23.87 μM for L-CDs-PP and 2.39 μM for D-CDs-PP. Importantly, the solid-state sensors successfully achieved dual-mode visual and portable detection of Arg with the support of a smartphone platform. In addition, L-CDs-PP and D-CDs-PP exhibited excellent biocompatibility and cell imaging capabilities, and they could achieve the detection of Arg in cells and biological samples of urine and rat plasma. Therefore, the dual ratiometric fluorescence sensors exhibited broad application prospects in the fields of analytical sensing, biological imaging, and medical diagnosis.

Figshare
Openalex Percentile: Top 64%
Carbon and Quantum Dots Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.