Application of electrical method to vertical HDPE film detection in landfill

According to the structure characteristics and site conditions of vertical HDPE film, the resistivity method is applied to the detection of vertical HDPE film. The double-arranged high-density electrical method was used to collect the data of vertical HDPE film, reverse the distribution of the profile resistivity on the vertical film, and detect the integrity of vertical HDPE film. The test was conducted combined with a landfill in Yancheng City, Jiangsu Province. And through site excavation, the effectiveness of resistivity method in vertical HDPE film detection was verified, and the shortcomings of traditional detection methods were solved. The experimental results show that: resistivity method can effectively, quickly and accurately locate shallow holes. Due to the presence of leachate, low-resistivity anomalies appear near the defects.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-04-17
DOI
https://doi.org/10.1051/e3sconf/202562502005/pdf
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of electrical method to vertical HDPE film detection in landfill

Springer Link (Chiba Institute of Technology)
Concrete Corrosion and Durability
article

Application of electrical method to vertical HDPE film detection in landfill

article en

Abstract

According to the structure characteristics and site conditions of vertical HDPE film, the resistivity method is applied to the detection of vertical HDPE film. The double-arranged high-density electrical method was used to collect the data of vertical HDPE film, reverse the distribution of the profile resistivity on the vertical film, and detect the integrity of vertical HDPE film. The test was conducted combined with a landfill in Yancheng City, Jiangsu Province. And through site excavation, the effectiveness of resistivity method in vertical HDPE film detection was verified, and the shortcomings of traditional detection methods were solved. The experimental results show that: resistivity method can effectively, quickly and accurately locate shallow holes. Due to the presence of leachate, low-resistivity anomalies appear near the defects.

Springer Link (Chiba Institute of Technology)
Sustainable cities and communities
Openalex Percentile: Top 56%
Concrete Corrosion and Durability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.