Impact of probe tilt on Graf ultrasonography accuracy for neonatal hip dysplasia screening

Background/objective: Developmental Dysplasia of the Hip (DDH) is the most common congenital musculoskeletal disease of the infantile age. The gold standard for early diagnosis of the disease is the Graf ultrasound method. In our study, we examined the correlation between age of the examined infant and diagnostic errors due to the ultrasound probe tilt effect during examination. Methods: Forty-two newborns who underwent ultrasound examination with the Graf method, were included. We categorized the neonates into three age groups (Group#1: 0–1 weeks, Group#2: 3–4 weeks, Group#3: 5–6weeks). Two ultrasound examinations were performed in every group. In the first examination, images were obtained with the probe in vertical position. In the second examination, images were taken with a 10° caudocranial tilt of the probe. Our aim was to measure the α angle in both examination and to mention the possible Type changes according to the Graf classification. The α angle defines the osseous coverage of the femoral head from the acetabulum in the neonatal hip joint. Results: In many cases, the classification changed from type I to type IIa or D and from type IIa to D, when instead of the vertical acquisition, the ultrasound probe was placed in a 10° caudocranial tilt at the hip joint of the examined infant. At Group#1 of the study we observed 60 Graf classification Type changes (90.91%), while in Group#2 and Group#3 we had 18 (33.33%) and 3 (7.96%) Type changes respectively. Conclusion: As the age of the examined newborns increases, measurement and classification errors due to the tilt effect are significantly reduced. Clinically, the examination will be even more accurate and the use of an incorrect therapeutic approach due to incorrect classification will be avoided. Finally, the optimal time for conducting an ultrasonographic examination is between the 5th and 6th week of life.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-04-01
DOI
https://doi.org/10.1051/sicotj/2025016/pdf
Primary Topic
Hip disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of probe tilt on Graf ultrasonography accuracy for neonatal hip dysplasia screening

Springer Link (Chiba Institute of Technology)
Hip disorders and treatments
article

Impact of probe tilt on Graf ultrasonography accuracy for neonatal hip dysplasia screening

article en

Abstract

Background/objective: Developmental Dysplasia of the Hip (DDH) is the most common congenital musculoskeletal disease of the infantile age. The gold standard for early diagnosis of the disease is the Graf ultrasound method. In our study, we examined the correlation between age of the examined infant and diagnostic errors due to the ultrasound probe tilt effect during examination. Methods: Forty-two newborns who underwent ultrasound examination with the Graf method, were included. We categorized the neonates into three age groups (Group#1: 0–1 weeks, Group#2: 3–4 weeks, Group#3: 5–6weeks). Two ultrasound examinations were performed in every group. In the first examination, images were obtained with the probe in vertical position. In the second examination, images were taken with a 10° caudocranial tilt of the probe. Our aim was to measure the α angle in both examination and to mention the possible Type changes according to the Graf classification. The α angle defines the osseous coverage of the femoral head from the acetabulum in the neonatal hip joint. Results: In many cases, the classification changed from type I to type IIa or D and from type IIa to D, when instead of the vertical acquisition, the ultrasound probe was placed in a 10° caudocranial tilt at the hip joint of the examined infant. At Group#1 of the study we observed 60 Graf classification Type changes (90.91%), while in Group#2 and Group#3 we had 18 (33.33%) and 3 (7.96%) Type changes respectively. Conclusion: As the age of the examined newborns increases, measurement and classification errors due to the tilt effect are significantly reduced. Clinically, the examination will be even more accurate and the use of an incorrect therapeutic approach due to incorrect classification will be avoided. Finally, the optimal time for conducting an ultrasonographic examination is between the 5th and 6th week of life.

Springer Link (Chiba Institute of Technology)
Good health and well-being
Openalex Percentile: Top 38%
Hip disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of probe tilt on Graf ultrasonography accuracy for neonatal hip dysplasia screening · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS