PhotoelectrochemicalBiosensor Based on TiO<sub>2</sub>/P5FIn with a Cascade AmplificationStrategy for Simultaneous Detectionof GSH and E2 Analytes of Ovarian Cancer

In this work, a photoelectrochemical (PEC) sensor for ovarian cancer detection was constructed based on TiO<sub>2</sub>/poly(5-formylindole) (P5FIn)heterojunction using cascade amplification. The combined detection of multiple markers instead of a single detection mode can improve diagnostic accuracy. The photoelectron conversion efficiency and photocurrent response were significantly improved by the reaction of the detector glutathione (GSH) with cystine. 17β-Estradiol (E2) had a negative effect on the PEC response, reducing the photocurrent signal, and ultimately realizing the sensitive detection of GSH and E2. The PEC sensor had good detection performance for GSH and E2, with a linear detection range (LDR) of 0.5–1000 μM, and the limits of detection (LOD) were 0.167 μM and 0.1224 pM, respectively, with a detection range of 0.0003671–36.71 nM. Meanwhile, the PEC sensor also has good analytical capability, and this cascade signal amplification strategy has a potential development prospect in disease detection.

Publication Details

Journal
Figshare
Published
2025-03-17
DOI
https://doi.org/10.1021/acs.analchem.4c06302.s001
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PhotoelectrochemicalBiosensor Based on TiO2/P5FIn with a Cascade AmplificationStrategy for Simultaneous Detectionof GSH and E2 Analytes of Ovarian Cancer

Figshare
Advanced biosensing and bioanalysis techniques
article

PhotoelectrochemicalBiosensor Based on TiO2/P5FIn with a Cascade AmplificationStrategy for Simultaneous Detectionof GSH and E2 Analytes of Ovarian Cancer

article en

Abstract

In this work, a photoelectrochemical (PEC) sensor for ovarian cancer detection was constructed based on TiO<sub>2</sub>/poly(5-formylindole) (P5FIn)heterojunction using cascade amplification. The combined detection of multiple markers instead of a single detection mode can improve diagnostic accuracy. The photoelectron conversion efficiency and photocurrent response were significantly improved by the reaction of the detector glutathione (GSH) with cystine. 17β-Estradiol (E2) had a negative effect on the PEC response, reducing the photocurrent signal, and ultimately realizing the sensitive detection of GSH and E2. The PEC sensor had good detection performance for GSH and E2, with a linear detection range (LDR) of 0.5–1000 μM, and the limits of detection (LOD) were 0.167 μM and 0.1224 pM, respectively, with a detection range of 0.0003671–36.71 nM. Meanwhile, the PEC sensor also has good analytical capability, and this cascade signal amplification strategy has a potential development prospect in disease detection.

Figshare
Openalex Percentile: Top 61%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.