High Resolving\nPower Electrospray Ionization Ion Mobility\nSpectrometer Based on Fourier Deconvolution Multiplexing

The resolving power of the drift\ntube ion mobility spectrometry\n(IMS) is mainly dependent on the drift length, the drift voltage,\nthe pulse width of an ion gate, and the pressure inside the drift\ntube. Electrospray ionization (ESI)-IMS is a highly sensitive and\nreliable technique for the detection and analysis of nonvolatile compounds,\nand high resolving power is necessary to separate structurally similar\ncompounds. To improve the analytical performance of atmospheric pressure\nESI-IMS, the Fourier deconvolution (FD) multiplexing technique is\ninvestigated as an effective and convenient means to improve the resolving\npower as well as the signal-to-noise ratio. By reducing the equivalent\nion gate opening width to 5 μs using a typical Tyndall–Powell\nion shutter, a high resolving power <i>R</i><sub>P</sub> up to 170 can be achieved with a drift length of 12 cm and a drift\nvoltage of 10 kV. Rhodamine 6G (R6G), sodium dodecyl sulfate (SDS),\nmethacycline, oxytetracycline, and ractopamine were evaluated using\nthe FD-ESI-IMS, and mixtures with similar ion mobility can be well\nseparated without prolonging the drift length.

Publication Details

Journal
Figshare
Published
2024-10-16
DOI
https://doi.org/10.1021/acs.analchem.4c04549.s001
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High Resolving\nPower Electrospray Ionization Ion Mobility\nSpectrometer Based on Fourier Deconvolution Multiplexing

Figshare
Mass Spectrometry Techniques and Applications
article

High Resolving\nPower Electrospray Ionization Ion Mobility\nSpectrometer Based on Fourier Deconvolution Multiplexing

article en

Abstract

The resolving power of the drift\ntube ion mobility spectrometry\n(IMS) is mainly dependent on the drift length, the drift voltage,\nthe pulse width of an ion gate, and the pressure inside the drift\ntube. Electrospray ionization (ESI)-IMS is a highly sensitive and\nreliable technique for the detection and analysis of nonvolatile compounds,\nand high resolving power is necessary to separate structurally similar\ncompounds. To improve the analytical performance of atmospheric pressure\nESI-IMS, the Fourier deconvolution (FD) multiplexing technique is\ninvestigated as an effective and convenient means to improve the resolving\npower as well as the signal-to-noise ratio. By reducing the equivalent\nion gate opening width to 5 μs using a typical Tyndall–Powell\nion shutter, a high resolving power <i>R</i><sub>P</sub> up to 170 can be achieved with a drift length of 12 cm and a drift\nvoltage of 10 kV. Rhodamine 6G (R6G), sodium dodecyl sulfate (SDS),\nmethacycline, oxytetracycline, and ractopamine were evaluated using\nthe FD-ESI-IMS, and mixtures with similar ion mobility can be well\nseparated without prolonging the drift length.

Figshare
Affordable and clean energy
Openalex Percentile: Top 75%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.