An Affordable Amperometric\nGas Sensor Based on Polyvinylidene\nFluoride Solid-State Electrolyte for Highly Selective Detection of\nppm-Level H<sub>2</sub> at Room Temperature

Currently, the assessment of irritable bowel syndrome\n(IBS) through\nthe detection of H<sub>2</sub> levels in exhaled breath using commercial\ngas sensors remains a challenging task. In this work, we presented\na cost-effective amperometric gas sensor capable of monitoring parts\nper million-level H<sub>2</sub> at room temperature by grafting polystyrene\nsulfonic acid onto polyvinylidene fluoride (PVDF-<i>g</i>-PSSA), creating a thermal stable and highly adaptable solid polymer\nelectrolyte. This PVDF-<i>g</i>-PSSA exhibited a high tensile\nstress value of 9.72 MPa and ionic conductivity of 2.73 × 10<sup>–2</sup> S cm<sup>–1</sup>, which is comparable with\nthat of the Nafion N115 membrane. The amperometric gas sensor based\non the PVDF-<i>g</i>-PSSA membrane exhibited preferable\nsensing performance, including a response current of 174.3 nA to 50\nppm of H<sub>2</sub> at room temperature and 50% relative humidity.\nAdditionally, it also displayed an acceptable response–recovery\ntime of 96 and 54 s, limit of detection (LOD) of 1 ppm H<sub>2</sub>, and selectivity for H<sub>2</sub> over other interfering gases.\nRemarkably, this sensor demonstrated a highly linear relationship\n(4.6 nA/ppm H<sub>2</sub>) with a correlation coefficient of 0.9998.\nFurthermore, we also applied this sensor to distinguish parts per\nmillion-level H<sub>2</sub> concentrations in simulated exhaled breath.\nThese findings demonstrated an affordable amperometric H<sub>2</sub> gas sensor for detecting ppm-level H<sub>2</sub> at room temperature,\neven without requiring a bias, thereby promising for biomarker detection\nin exhaled breath.

Publication Details

Journal
Figshare
Published
2024-10-09
DOI
https://doi.org/10.1021/acsapm.4c01616.s001
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Affordable Amperometric\nGas Sensor Based on Polyvinylidene\nFluoride Solid-State Electrolyte for Highly Selective Detection of\nppm-Level H2 at Room Temperature

Figshare
Gas Sensing Nanomaterials and Sensors
article

An Affordable Amperometric\nGas Sensor Based on Polyvinylidene\nFluoride Solid-State Electrolyte for Highly Selective Detection of\nppm-Level H2 at Room Temperature

article en

Abstract

Currently, the assessment of irritable bowel syndrome\n(IBS) through\nthe detection of H<sub>2</sub> levels in exhaled breath using commercial\ngas sensors remains a challenging task. In this work, we presented\na cost-effective amperometric gas sensor capable of monitoring parts\nper million-level H<sub>2</sub> at room temperature by grafting polystyrene\nsulfonic acid onto polyvinylidene fluoride (PVDF-<i>g</i>-PSSA), creating a thermal stable and highly adaptable solid polymer\nelectrolyte. This PVDF-<i>g</i>-PSSA exhibited a high tensile\nstress value of 9.72 MPa and ionic conductivity of 2.73 × 10<sup>–2</sup> S cm<sup>–1</sup>, which is comparable with\nthat of the Nafion N115 membrane. The amperometric gas sensor based\non the PVDF-<i>g</i>-PSSA membrane exhibited preferable\nsensing performance, including a response current of 174.3 nA to 50\nppm of H<sub>2</sub> at room temperature and 50% relative humidity.\nAdditionally, it also displayed an acceptable response–recovery\ntime of 96 and 54 s, limit of detection (LOD) of 1 ppm H<sub>2</sub>, and selectivity for H<sub>2</sub> over other interfering gases.\nRemarkably, this sensor demonstrated a highly linear relationship\n(4.6 nA/ppm H<sub>2</sub>) with a correlation coefficient of 0.9998.\nFurthermore, we also applied this sensor to distinguish parts per\nmillion-level H<sub>2</sub> concentrations in simulated exhaled breath.\nThese findings demonstrated an affordable amperometric H<sub>2</sub> gas sensor for detecting ppm-level H<sub>2</sub> at room temperature,\neven without requiring a bias, thereby promising for biomarker detection\nin exhaled breath.

Figshare
Openalex Percentile: Top 69%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Affordable Amperometric\nGas Sensor Based on Polyvinylidene\nFluoride Solid-State Electrolyte for Highly Selective Detection of\nppm-Level H<sub>2</sub> at Room Temperature · Figshare (2024) | TGRS Research Map | TGRS