Sensitive and Simple Electroanalytical Method for Lead Detection in Seawater Using VAdS with Eriochrome Blue Black R

A novel electroanalytical approach for lead detection was developed using the voltammetric adsorptive stripping (VAdS) method with Eriochrome Blue Black R (EBBR) as the complexing agent. The method operates by accumulating the Lead-EBBR complex on a hanging mercury drop electrode (HMDE) and measuring the peak current. The complex reduces at -0.46 V, with the peak current increasing as small amounts of EBBR are introduced into the sample. Key parameters such as pH, EBBR concentration, accumulation time (tacc), and accumulation potential (Eacc) were optimized. Under optimal conditions (pH 3, 0.6 mol/L EBBR, tacc 60 s, Eacc 0.35 V, and 40 mmol buffer), the peak current correlated directly with Lead (II) concentrations from 0.05 to 100 µg/L, with a detection limit of 0.01 µg/L. The method exhibited high precision, with a relative standard deviation of 0.5% for a 10 µg/L Lead (II) solution over ten trials. Validation of the method was achieved by comparing results from seawater samples from former bauxite mining areas, using Atomic Absorption Spectrophotometry (AAS), showing similar outcomes. The VAdS method proved highly effective for detecting Lead (II) in seawater contaminated by mining waste.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-10-28
DOI
https://doi.org/10.1051/bioconf/202413406015/pdf
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitive and Simple Electroanalytical Method for Lead Detection in Seawater Using VAdS with Eriochrome Blue Black R

Springer Link (Chiba Institute of Technology)
Electrochemical Analysis and Applications
article

Sensitive and Simple Electroanalytical Method for Lead Detection in Seawater Using VAdS with Eriochrome Blue Black R

article en

Abstract

A novel electroanalytical approach for lead detection was developed using the voltammetric adsorptive stripping (VAdS) method with Eriochrome Blue Black R (EBBR) as the complexing agent. The method operates by accumulating the Lead-EBBR complex on a hanging mercury drop electrode (HMDE) and measuring the peak current. The complex reduces at -0.46 V, with the peak current increasing as small amounts of EBBR are introduced into the sample. Key parameters such as pH, EBBR concentration, accumulation time (tacc), and accumulation potential (Eacc) were optimized. Under optimal conditions (pH 3, 0.6 mol/L EBBR, tacc 60 s, Eacc 0.35 V, and 40 mmol buffer), the peak current correlated directly with Lead (II) concentrations from 0.05 to 100 µg/L, with a detection limit of 0.01 µg/L. The method exhibited high precision, with a relative standard deviation of 0.5% for a 10 µg/L Lead (II) solution over ten trials. Validation of the method was achieved by comparing results from seawater samples from former bauxite mining areas, using Atomic Absorption Spectrophotometry (AAS), showing similar outcomes. The VAdS method proved highly effective for detecting Lead (II) in seawater contaminated by mining waste.

Springer Link (Chiba Institute of Technology)
Life below water
Openalex Percentile: Top 73%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.