Ionic ElectroactivePolymer Actuators Using QuaternaryAmmonium Iodide (QAI) Containing Hydrogels Operational at Low Voltages

Quaternary ammonium iodide (QAI)-containing hydrogels with different alkyl side chain lengths were synthesized and used to develop ionic electroactive strip actuators. The strip bent at relatively low voltages, exhibiting a 5.0 mm bending displacement over the 30 mm strip length at 0.6 V, for example. The bending displacement largely depended on the applied voltages and alkyl side chain lengths. The anticipated bending mechanism is the movement of the iodide anions toward the anode, thereby driving volume contrast in the strip near the anode (volume expansion) and cathode (volume contraction). This mechanism was experimentally confirmed by monitoring the location of the iodide anions in the strip by using scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM-EDX) and confocal microscopy. The obtained QAI-containing actuators are operational at relatively low voltages and in water-containing environments and also have antimicrobial properties, which would be useful for biological environment applications.

Publication Details

Journal
Figshare
Published
2025-03-11
DOI
https://doi.org/10.1021/acsapm.5c00005.s001
Primary Topic
Dielectric materials and actuators
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ionic ElectroactivePolymer Actuators Using QuaternaryAmmonium Iodide (QAI) Containing Hydrogels Operational at Low Voltages

Figshare
Dielectric materials and actuators
article

Ionic ElectroactivePolymer Actuators Using QuaternaryAmmonium Iodide (QAI) Containing Hydrogels Operational at Low Voltages

article en

Abstract

Quaternary ammonium iodide (QAI)-containing hydrogels with different alkyl side chain lengths were synthesized and used to develop ionic electroactive strip actuators. The strip bent at relatively low voltages, exhibiting a 5.0 mm bending displacement over the 30 mm strip length at 0.6 V, for example. The bending displacement largely depended on the applied voltages and alkyl side chain lengths. The anticipated bending mechanism is the movement of the iodide anions toward the anode, thereby driving volume contrast in the strip near the anode (volume expansion) and cathode (volume contraction). This mechanism was experimentally confirmed by monitoring the location of the iodide anions in the strip by using scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM-EDX) and confocal microscopy. The obtained QAI-containing actuators are operational at relatively low voltages and in water-containing environments and also have antimicrobial properties, which would be useful for biological environment applications.

Figshare
Openalex Percentile: Top 58%
Dielectric materials and actuators
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.