Enhancing Amperometric\nOzone Gas Sensing with Room-Temperature\nIonic Liquids and Platinum-Based Electrodes

Ozone (O<sub>3</sub>) poses serious health risks, prompting\nnumerous\ncountries to implement regulations that establish exposure limits\nand emission controls, for example, the air quality index (AQI) for\nO<sub>3</sub> ranging from 50 to 150 parts per billion (ppb), with\nnatural\nlevels at around 30 ppb. Electrochemical sensors are favored for detecting\npollutant gases due to their high sensitivity, low cost, portability,\nenergy efficiency, and capability for selective detection. In this\nstudy, we developed an O<sub>3</sub> sensor employing carbon-supported\nPt-based binary and ternary nanorods\n(NRs) combined with room-temperature ionic liquids (RTILs) as electrolytes,\naiming at highly sensitive and selective detection of O<sub>3</sub> at ppb levels. Initial screening of\nthe O<sub>3</sub> sensing performance across different electrolytes\nidentified H<sub>2</sub>SO<sub>4</sub> and [C<sub>4</sub>mpyrr][NTf<sub>2</sub>] (BMP) as the most sensitive options. BMP outperformed H<sub>2</sub>SO<sub>4</sub> in terms of linearity, selectivity, reproducibility,\nand response/recovery times, despite a relatively lower sensitivity.\nElectrochemical testing of Pt, PtAu, PtAg, and PtAuAg NR electrodes\nin BMP revealed that the addition of Au enhanced the linear response,\nwhile Ag improved sensitivity. Consequently, the ternary PtAuAg NR\nelectrode exhibited the highest sensitivity (10.5 nA/ppm (parts per\nmillion)) and a broad detection range, fulfilling the AQI requirements\nfor O<sub>3</sub>. The current response from the PtAuAg NR electrode\nclosely aligned with results from an ultraviolet (UV) photometric\nanalyzer, confirming its accuracy. Notably, this electrode contains\nonly 20 wt % noble metals, which reduces the overall cost to just\n11% of that of a traditional pure Au electrode.

Publication Details

Journal
Figshare
Published
2024-12-18
DOI
https://doi.org/10.1021/acsami.4c18003.s001
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Amperometric\nOzone Gas Sensing with Room-Temperature\nIonic Liquids and Platinum-Based Electrodes

Figshare
Gas Sensing Nanomaterials and Sensors
article

Enhancing Amperometric\nOzone Gas Sensing with Room-Temperature\nIonic Liquids and Platinum-Based Electrodes

article en

Abstract

Ozone (O<sub>3</sub>) poses serious health risks, prompting\nnumerous\ncountries to implement regulations that establish exposure limits\nand emission controls, for example, the air quality index (AQI) for\nO<sub>3</sub> ranging from 50 to 150 parts per billion (ppb), with\nnatural\nlevels at around 30 ppb. Electrochemical sensors are favored for detecting\npollutant gases due to their high sensitivity, low cost, portability,\nenergy efficiency, and capability for selective detection. In this\nstudy, we developed an O<sub>3</sub> sensor employing carbon-supported\nPt-based binary and ternary nanorods\n(NRs) combined with room-temperature ionic liquids (RTILs) as electrolytes,\naiming at highly sensitive and selective detection of O<sub>3</sub> at ppb levels. Initial screening of\nthe O<sub>3</sub> sensing performance across different electrolytes\nidentified H<sub>2</sub>SO<sub>4</sub> and [C<sub>4</sub>mpyrr][NTf<sub>2</sub>] (BMP) as the most sensitive options. BMP outperformed H<sub>2</sub>SO<sub>4</sub> in terms of linearity, selectivity, reproducibility,\nand response/recovery times, despite a relatively lower sensitivity.\nElectrochemical testing of Pt, PtAu, PtAg, and PtAuAg NR electrodes\nin BMP revealed that the addition of Au enhanced the linear response,\nwhile Ag improved sensitivity. Consequently, the ternary PtAuAg NR\nelectrode exhibited the highest sensitivity (10.5 nA/ppm (parts per\nmillion)) and a broad detection range, fulfilling the AQI requirements\nfor O<sub>3</sub>. The current response from the PtAuAg NR electrode\nclosely aligned with results from an ultraviolet (UV) photometric\nanalyzer, confirming its accuracy. Notably, this electrode contains\nonly 20 wt % noble metals, which reduces the overall cost to just\n11% of that of a traditional pure Au electrode.

Figshare
Openalex Percentile: Top 69%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.