Lens-Free Holographic Imaging-Based Immunosensor UsingUnpaired Data Set Signal-to-Noise Ratio-Enhanced Modal Transformationfor Biosensing

Conventional microscopes have limited capacities to reconcile the trade-off between the lens and field of view (FOV). Thus, the imaging field and accuracy of immunosensors remain restricted. In this study, a holographic deep learning unpaired modal transformation-assisted immunosensor is presented, combining a portable lens-free holographic imaging device with a CuO<sub>2</sub>@SiO<sub>2</sub> nanoparticle-based click reaction signal amplification strategy for accurate antibiotic detection. The immunosensor achieves both large FOV imaging (10.3-fold improvement over the microscope) and signal-to-noise ratio-enhanced holographic reconstruction (signal-to-noise ratio of 32.65 dB, structural similarity index of 0.83) by constructing a modal transformation model with unpaired data sets, thus resolving the complexity of one-to-one matching of data sets required by conventional methods. The immunosensor detects chloramphenicol with high sensitivity and a wide linear range (limit of detection = 3.54 pg/mL, dynamic range of 10 pg/mL to 50 ng/mL) within 40 min. As a portable detection device, it demonstrates potential as a sensitive and on-site detection platform for food safety inspection and clinical diagnosis.

Publication Details

Journal
Figshare
Published
2025-02-04
DOI
https://doi.org/10.1021/acs.analchem.4c04453.s001
Primary Topic
Digital Holography and Microscopy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lens-Free Holographic Imaging-Based Immunosensor UsingUnpaired Data Set Signal-to-Noise Ratio-Enhanced Modal Transformationfor Biosensing

Figshare
Digital Holography and Microscopy
article

Lens-Free Holographic Imaging-Based Immunosensor UsingUnpaired Data Set Signal-to-Noise Ratio-Enhanced Modal Transformationfor Biosensing

article en

Abstract

Conventional microscopes have limited capacities to reconcile the trade-off between the lens and field of view (FOV). Thus, the imaging field and accuracy of immunosensors remain restricted. In this study, a holographic deep learning unpaired modal transformation-assisted immunosensor is presented, combining a portable lens-free holographic imaging device with a CuO<sub>2</sub>@SiO<sub>2</sub> nanoparticle-based click reaction signal amplification strategy for accurate antibiotic detection. The immunosensor achieves both large FOV imaging (10.3-fold improvement over the microscope) and signal-to-noise ratio-enhanced holographic reconstruction (signal-to-noise ratio of 32.65 dB, structural similarity index of 0.83) by constructing a modal transformation model with unpaired data sets, thus resolving the complexity of one-to-one matching of data sets required by conventional methods. The immunosensor detects chloramphenicol with high sensitivity and a wide linear range (limit of detection = 3.54 pg/mL, dynamic range of 10 pg/mL to 50 ng/mL) within 40 min. As a portable detection device, it demonstrates potential as a sensitive and on-site detection platform for food safety inspection and clinical diagnosis.

Figshare
Zero hunger
Openalex Percentile: Top 63%
Digital Holography and Microscopy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.