Ratio Fluorescence Detection of Salicylic Acid Basedon Ti<sub>3</sub>C<sub>2</sub> Quantum Dots

Ti<sub>3</sub>C<sub>2</sub> QDs with stable blue luminescence at 352 nm were synthesized by using arginine (Arg) as a ligand. Based on the interaction between salicylic acid (SA) and Arg-Ti<sub>3</sub>C<sub>2</sub> QDs, an enhanced ratio fluorescence sensor was constructed for fluorescence detection of SA. When SA was added to the system, fluorescence through the internal filtration effect (IFE) of Arg-Ti<sub>3</sub>C<sub>2</sub> QDs at 352 nm was gradually weakened, while the interaction between SA and Arg-Ti<sub>3</sub>C<sub>2</sub> QDs through hydrogen led to the appearance and significant enhancement of fluorescence at 403.9 nm, leading to ratio fluorescence. The system has a good detection limit (LOD) of 0.57 μM and excellent selectivity. And it can be applied to the detection of SA in the essence of actual samples, which can effectively prevent harm to the human body caused by adding too much SA in cosmetics.

Publication Details

Journal
Figshare
Published
2025-03-21
DOI
https://doi.org/10.1021/acsanm.4c07332.s001
Primary Topic
MXene and MAX Phase Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ratio Fluorescence Detection of Salicylic Acid Basedon Ti3C2 Quantum Dots

Figshare
MXene and MAX Phase Materials
article

Ratio Fluorescence Detection of Salicylic Acid Basedon Ti3C2 Quantum Dots

article en

Abstract

Ti<sub>3</sub>C<sub>2</sub> QDs with stable blue luminescence at 352 nm were synthesized by using arginine (Arg) as a ligand. Based on the interaction between salicylic acid (SA) and Arg-Ti<sub>3</sub>C<sub>2</sub> QDs, an enhanced ratio fluorescence sensor was constructed for fluorescence detection of SA. When SA was added to the system, fluorescence through the internal filtration effect (IFE) of Arg-Ti<sub>3</sub>C<sub>2</sub> QDs at 352 nm was gradually weakened, while the interaction between SA and Arg-Ti<sub>3</sub>C<sub>2</sub> QDs through hydrogen led to the appearance and significant enhancement of fluorescence at 403.9 nm, leading to ratio fluorescence. The system has a good detection limit (LOD) of 0.57 μM and excellent selectivity. And it can be applied to the detection of SA in the essence of actual samples, which can effectively prevent harm to the human body caused by adding too much SA in cosmetics.

Figshare
Openalex Percentile: Top 64%
MXene and MAX Phase Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.