Experimental investigation of heat transfer enhancement with radially arrayed delta winglets in a heat exchanger tube

Delta winglets are one of the promising and effective vortex generators (VGs) for enhancing heat transfer, with a low pressure drop penalty. This research is concerned with innovative arrangements (inline, staggered, mixed configurations) of delta winglet vortex generators (VGs) inside a circular tube to investigate their effects on thermal and flow characteristics. The VGs were arranged inside a tube as a series of four rings. Each ring had four winglets on the inner surface of the tube. Experimental measurements with VG inserts were conducted for fully developed turbulent air flows with Reynolds numbers between 6000 and 27,000 under a constant heat flux condition on the surface of the tube. The experimental results show that delta winglets with different arrangements lead to significant thermal performance enhancement. Using the staggered configuration instead of inline configuration of the VGs resulted in a significant drop in friction factor (6 %) and a significant increase in Nusselt number (16 %). Compared to the inline configuration, staggered configurations of VGs provided better heat exchanger performance. The highest Thermal Performance Enhancement (TPE) obtained, 1.33, was achieved using mixed VG directions with a staggered VG arrangement (i.e., configuration referred to as RZ1). The effects of VG length, rotational direction, and inward and backward positions of VGs on thermal performance were also characterized. Rotational directions (positive and negative) were found to have a positive impact on the Nusselt number ( Nu ) and a small effect on the friction factor ( f). Increasing the length of the VGs resulted in an increase of f and Nu . This study suggests that innovative layouts/arrangements of VGs can contribute to the development of high-performance heat exchangers.

Institutions

Publication Details

Journal
International Communications in Heat and Mass Transfer
Published
2025-07-18
DOI
https://doi.org/10.1016/j.icheatmasstransfer.2025.109357
Primary Topic
Plasma and Flow Control in Aerodynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation of heat transfer enhancement with radially arrayed delta winglets in a heat exchanger tube

International Communications in Heat and Mass Transfer
Plasma and Flow Control in Aerodynamics
article

Experimental investigation of heat transfer enhancement with radially arrayed delta winglets in a heat exchanger tube

article en

Abstract

Delta winglets are one of the promising and effective vortex generators (VGs) for enhancing heat transfer, with a low pressure drop penalty. This research is concerned with innovative arrangements (inline, staggered, mixed configurations) of delta winglet vortex generators (VGs) inside a circular tube to investigate their effects on thermal and flow characteristics. The VGs were arranged inside a tube as a series of four rings. Each ring had four winglets on the inner surface of the tube. Experimental measurements with VG inserts were conducted for fully developed turbulent air flows with Reynolds numbers between 6000 and 27,000 under a constant heat flux condition on the surface of the tube. The experimental results show that delta winglets with different arrangements lead to significant thermal performance enhancement. Using the staggered configuration instead of inline configuration of the VGs resulted in a significant drop in friction factor (6 %) and a significant increase in Nusselt number (16 %). Compared to the inline configuration, staggered configurations of VGs provided better heat exchanger performance. The highest Thermal Performance Enhancement (TPE) obtained, 1.33, was achieved using mixed VG directions with a staggered VG arrangement (i.e., configuration referred to as RZ1). The effects of VG length, rotational direction, and inward and backward positions of VGs on thermal performance were also characterized. Rotational directions (positive and negative) were found to have a positive impact on the Nusselt number ( Nu ) and a small effect on the friction factor ( f). Increasing the length of the VGs resulted in an increase of f and Nu . This study suggests that innovative layouts/arrangements of VGs can contribute to the development of high-performance heat exchangers.

International Communications in Heat and Mass TransferVol. 167
American University in Dubai (AE), Shenzhen Institute of Information Technology (CN), Khalifa University of Science and Technology (AE), Texas A&M University (US)
Affordable and clean energy
Openalex Percentile: Top 45%
Plasma and Flow Control in Aerodynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.