PhotothermalDesorption and Reagent-Assisted Low-TemperaturePlasma Ionization Miniature IT-MS/MS for On-Site Analysis of IllicitDrugs in Saliva and Urine

Globally, drug-impaired driving fatalities now exceed those from drunk driving, urging the need for on-site and roadside detection methods. In this study, a photothermal desorption and reagent-assisted low-temperature plasma ionization miniature ion trap mass spectrometer (PDRA-LTP-ITMS) was developed for on-site detection of drug-impaired driving. The pseudomultiple reaction monitoring (MRM) in PDRA-LTP-ITMS enables continuous ion selection during ion introduction and improved sensitivity to nearly 3-fold compared with the conventional full scan mode. The PDRA-LTP integrated the ionization source and photothermal desorption region into the LTP tube with a volume of 0.05 mL. Photoionization and Penning ionization from LTP discharging facilitate proton transfer reactions with the dopant and produce characteristic [M + H]<sup>+</sup> for drugs. Dopants of butanol and acetone were separately employed to enhance the thermal desorption and ionization efficiency, resulting in a 2.6-fold sensitivity increase. Saliva and urine samples were collected with a medical swab, and only 10 μL of sample is required for each analysis. The sample is rapidly heated to 250 °C using a halogen lamp and analyzed within 5 s. With these designs, a 4-fold and 10-fold increase in sensitivity was achieved compared to APPI and nano-ESI, respectively. The limits of detection (S/N = 3) of illicit drugs, including MDMA, MDA, methamphetamine, amphetamine, ketamine, and cocaine, in saliva ranged from 4.5 pg μL <sup>–1</sup> to 20 pg μL<sup>–1</sup> and met the threshold values of GA1333–2017. The performance of the PDRA-LTP-ITMS was even comparable to that of LTQ-Orbitrap Velos Pro ETD MS, providing a novel method of rapid on-site drug-impaired driving analysis.

Publication Details

Journal
Figshare
Published
2025-01-28
DOI
https://doi.org/10.1021/acs.analchem.4c05146.s001
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PhotothermalDesorption and Reagent-Assisted Low-TemperaturePlasma Ionization Miniature IT-MS/MS for On-Site Analysis of IllicitDrugs in Saliva and Urine

Figshare
Mass Spectrometry Techniques and Applications
article

PhotothermalDesorption and Reagent-Assisted Low-TemperaturePlasma Ionization Miniature IT-MS/MS for On-Site Analysis of IllicitDrugs in Saliva and Urine

article en

Abstract

Globally, drug-impaired driving fatalities now exceed those from drunk driving, urging the need for on-site and roadside detection methods. In this study, a photothermal desorption and reagent-assisted low-temperature plasma ionization miniature ion trap mass spectrometer (PDRA-LTP-ITMS) was developed for on-site detection of drug-impaired driving. The pseudomultiple reaction monitoring (MRM) in PDRA-LTP-ITMS enables continuous ion selection during ion introduction and improved sensitivity to nearly 3-fold compared with the conventional full scan mode. The PDRA-LTP integrated the ionization source and photothermal desorption region into the LTP tube with a volume of 0.05 mL. Photoionization and Penning ionization from LTP discharging facilitate proton transfer reactions with the dopant and produce characteristic [M + H]<sup>+</sup> for drugs. Dopants of butanol and acetone were separately employed to enhance the thermal desorption and ionization efficiency, resulting in a 2.6-fold sensitivity increase. Saliva and urine samples were collected with a medical swab, and only 10 μL of sample is required for each analysis. The sample is rapidly heated to 250 °C using a halogen lamp and analyzed within 5 s. With these designs, a 4-fold and 10-fold increase in sensitivity was achieved compared to APPI and nano-ESI, respectively. The limits of detection (S/N = 3) of illicit drugs, including MDMA, MDA, methamphetamine, amphetamine, ketamine, and cocaine, in saliva ranged from 4.5 pg μL <sup>–1</sup> to 20 pg μL<sup>–1</sup> and met the threshold values of GA1333–2017. The performance of the PDRA-LTP-ITMS was even comparable to that of LTQ-Orbitrap Velos Pro ETD MS, providing a novel method of rapid on-site drug-impaired driving analysis.

Figshare
Good health and well-being
Openalex Percentile: Top 61%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.