Dual-Mode Immunosensorfor Antibody Detection: Harnessingthe Versatility of Antibody-Based Nanozymes across Optical and ElectrochemicalPlatforms

In the early years of the 21st century, numerous viral infectious diseases have proliferated, prompting intensified efforts to devise more effective diagnostic methods. In response, various biosensors have emerged with the aim of overcoming the constraints of conventional diagnostic techniques. Nanomaterial-based biosensors have revolutionized conventional approaches, significantly enhancing biosensor performance and effectively tackling these challenges. A diverse array of nanoparticles and nanomaterials has been systematically synthesized, engineered, and employed to augment the functionalities of biosensors. This work capitalizes on the properties of gold–platinum bimetallic nanoclusters (NCs) embedded in the structure of an immunoglobulin (IgG) (Au/Pt NCs-IgG), unveiling a novel double strategy for the detection of antibodies that leverages both their catalytic NC scaffold and the biorecognition element. The detection mechanism revealed the unique oxidase-like properties of Au/Pt NCs-IgG. This distinctive property, in addition to previously reported peroxidase-like activity, positions Au/Pt NCs-IgG as an effective probe in both optical and electrochemical sandwich enzyme-linked immunosorbent assays, facilitating their incorporation in different sensor frameworks and their utilization across various applications. As a study case, anti-SARS-CoV-2 antibodies (anti-RBD IgG antibodies) were employed as the target analyte. A linear detection range was found between 0.5 and 100 ng/mL for optical immunosensors and 50–300 ng/mL for electrochemical immunosensors. The validation of the immunosensor in clinical samples demonstrated its promising diagnostic value. The significantly differential signal obtained between positive and negative clinical samples underscores the suitability of both sensors for point-of-care diagnostic applications.

Publication Details

Journal
Figshare
Published
2025-02-07
DOI
https://doi.org/10.1021/acs.analchem.4c05317.s001
Primary Topic
Advanced Nanomaterials in Catalysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-Mode Immunosensorfor Antibody Detection: Harnessingthe Versatility of Antibody-Based Nanozymes across Optical and ElectrochemicalPlatforms

Figshare
Advanced Nanomaterials in Catalysis
article

Dual-Mode Immunosensorfor Antibody Detection: Harnessingthe Versatility of Antibody-Based Nanozymes across Optical and ElectrochemicalPlatforms

article en

Abstract

In the early years of the 21st century, numerous viral infectious diseases have proliferated, prompting intensified efforts to devise more effective diagnostic methods. In response, various biosensors have emerged with the aim of overcoming the constraints of conventional diagnostic techniques. Nanomaterial-based biosensors have revolutionized conventional approaches, significantly enhancing biosensor performance and effectively tackling these challenges. A diverse array of nanoparticles and nanomaterials has been systematically synthesized, engineered, and employed to augment the functionalities of biosensors. This work capitalizes on the properties of gold–platinum bimetallic nanoclusters (NCs) embedded in the structure of an immunoglobulin (IgG) (Au/Pt NCs-IgG), unveiling a novel double strategy for the detection of antibodies that leverages both their catalytic NC scaffold and the biorecognition element. The detection mechanism revealed the unique oxidase-like properties of Au/Pt NCs-IgG. This distinctive property, in addition to previously reported peroxidase-like activity, positions Au/Pt NCs-IgG as an effective probe in both optical and electrochemical sandwich enzyme-linked immunosorbent assays, facilitating their incorporation in different sensor frameworks and their utilization across various applications. As a study case, anti-SARS-CoV-2 antibodies (anti-RBD IgG antibodies) were employed as the target analyte. A linear detection range was found between 0.5 and 100 ng/mL for optical immunosensors and 50–300 ng/mL for electrochemical immunosensors. The validation of the immunosensor in clinical samples demonstrated its promising diagnostic value. The significantly differential signal obtained between positive and negative clinical samples underscores the suitability of both sensors for point-of-care diagnostic applications.

Figshare
Openalex Percentile: Top 64%
Advanced Nanomaterials in Catalysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.