Precise Light-Driven\nPolarity of Stationary Phase\nfor Regulating Gradient Separation of Liquid Chromatography

Generally, the traditional stationary phase for liquid\nchromatography\nis the key part, but with an in situ immutable property, leading to\nmany separation limitations. Based on the former exploration of photosensitive\ngas chromatography, we successfully prepared a photosensitive monolithic\ncapillary silica column with high light transmission, taking advantage\nof the reversible cis–trans isomerism of azobenzene. And the\ncis–trans isomerism has launched an effective, reversible,\nand precise control on the liquid chromatographic retention behavior\njust by photoinduction according to the theoretical basis of a good\ncorrelation between photoinduction time, <i>trans</i>-azobenzene\nratio, and chromatographic retention factor (<i>k</i>) (<i>R</i><sup>2</sup> > 0.9586). In this system, the plausible\ncontrol\nmechanism of stationary phase’s polarity is the synergistic\neffect of the self-molecular polarity difference and the occupation\n(or release) of polar groups on the stationary phase surface by cis–trans\nisomerism. Furthermore, a “light control–time ratio\ncycle” strategy was first reported to maintain an arbitrary\nratio of <i>trans</i>-azobenzene corresponding to the polarity\ngradient of the stationary phase during the whole chromatographic\nseparation process, which is verified by a close correlation of the\nretention time of the targets and the ratio of light-controlled time\n(<i>R</i><sup>2</sup> > 0.9977). The “gradient\nelution”\nof the targets was also surprisingly realized due to the gradient\nregulation of stationary phase’s polarity by the programmatic\ncontrol of alternate light induction and time ratio. This work further\nadvances the practical significance of photosensitive chromatography\nin “one column for multiple columns”, even “one\ncolumn for multidimensional chromatography”, and truly provides\nresearch foundation for its development in the separation and analysis\nof complex biological samples.

Publication Details

Journal
Figshare
Published
2024-12-25
DOI
https://doi.org/10.1021/acs.analchem.4c05545.s001
Primary Topic
Photochromic and Fluorescence Chemistry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precise Light-Driven\nPolarity of Stationary Phase\nfor Regulating Gradient Separation of Liquid Chromatography

Figshare
Photochromic and Fluorescence Chemistry
article

Precise Light-Driven\nPolarity of Stationary Phase\nfor Regulating Gradient Separation of Liquid Chromatography

article en

Abstract

Generally, the traditional stationary phase for liquid\nchromatography\nis the key part, but with an in situ immutable property, leading to\nmany separation limitations. Based on the former exploration of photosensitive\ngas chromatography, we successfully prepared a photosensitive monolithic\ncapillary silica column with high light transmission, taking advantage\nof the reversible cis–trans isomerism of azobenzene. And the\ncis–trans isomerism has launched an effective, reversible,\nand precise control on the liquid chromatographic retention behavior\njust by photoinduction according to the theoretical basis of a good\ncorrelation between photoinduction time, <i>trans</i>-azobenzene\nratio, and chromatographic retention factor (<i>k</i>) (<i>R</i><sup>2</sup> > 0.9586). In this system, the plausible\ncontrol\nmechanism of stationary phase’s polarity is the synergistic\neffect of the self-molecular polarity difference and the occupation\n(or release) of polar groups on the stationary phase surface by cis–trans\nisomerism. Furthermore, a “light control–time ratio\ncycle” strategy was first reported to maintain an arbitrary\nratio of <i>trans</i>-azobenzene corresponding to the polarity\ngradient of the stationary phase during the whole chromatographic\nseparation process, which is verified by a close correlation of the\nretention time of the targets and the ratio of light-controlled time\n(<i>R</i><sup>2</sup> > 0.9977). The “gradient\nelution”\nof the targets was also surprisingly realized due to the gradient\nregulation of stationary phase’s polarity by the programmatic\ncontrol of alternate light induction and time ratio. This work further\nadvances the practical significance of photosensitive chromatography\nin “one column for multiple columns”, even “one\ncolumn for multidimensional chromatography”, and truly provides\nresearch foundation for its development in the separation and analysis\nof complex biological samples.

Figshare
Openalex Percentile: Top 79%
Photochromic and Fluorescence Chemistry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.