Elevated PFASPrecursors in Septage and ResidentialPump Stations

Residential wastewater, with no industrial inputs, is an underrecognized source of per- and polyfluoroalkyl substances (PFAS). This study provides the first direct comparison of PFAS in septage and pump stations, targeting 70 PFAS compounds and employing the total oxidizable precursor (TOP) assay. Septage exhibited markedly higher PFAS and precursors concentrations than pump stations, with median post-TOP levels of 687.5 ng/L vs 84.2 ng/L, respectively. FTCAs were fully oxidized, while diPAPs showed incomplete oxidation due to high organic loads. Septic systems function as PFAS reservoirs, increasing risks of groundwater contamination, particularly in areas with shallow aquifers. Pump stations contributed to episodic PFAS spikes, likely affecting downstream wastewater treatment. The detection of 27 PFAS compounds, including short-chain alternatives, highlights shifting contamination patterns. Findings emphasize the need for tailored analytical frameworks and pretreatment technologies to mitigate PFAS risks across decentralized and centralized wastewater systems. Integrating precursor analysis is critical for accurate risk assessment, as targeted PFAS measurements underestimate contamination. These results provide new insights into PFAS behavior in residential wastewater, guiding future mitigation efforts.

Publication Details

Journal
Figshare
Published
2025-03-25
DOI
https://doi.org/10.1021/acs.estlett.5c00246.s002
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Elevated PFASPrecursors in Septage and ResidentialPump Stations

Figshare
Per- and polyfluoroalkyl substances research
article

Elevated PFASPrecursors in Septage and ResidentialPump Stations

article en

Abstract

Residential wastewater, with no industrial inputs, is an underrecognized source of per- and polyfluoroalkyl substances (PFAS). This study provides the first direct comparison of PFAS in septage and pump stations, targeting 70 PFAS compounds and employing the total oxidizable precursor (TOP) assay. Septage exhibited markedly higher PFAS and precursors concentrations than pump stations, with median post-TOP levels of 687.5 ng/L vs 84.2 ng/L, respectively. FTCAs were fully oxidized, while diPAPs showed incomplete oxidation due to high organic loads. Septic systems function as PFAS reservoirs, increasing risks of groundwater contamination, particularly in areas with shallow aquifers. Pump stations contributed to episodic PFAS spikes, likely affecting downstream wastewater treatment. The detection of 27 PFAS compounds, including short-chain alternatives, highlights shifting contamination patterns. Findings emphasize the need for tailored analytical frameworks and pretreatment technologies to mitigate PFAS risks across decentralized and centralized wastewater systems. Integrating precursor analysis is critical for accurate risk assessment, as targeted PFAS measurements underestimate contamination. These results provide new insights into PFAS behavior in residential wastewater, guiding future mitigation efforts.

Figshare
Clean water and sanitation
Openalex Percentile: Top 61%
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.