A Determination of e/m from the Zeeman Effect

Values of e/m have been obtained from the Zeeman separations of the Cd line λ 6439 and the Zn line λ 6362, the g-factors of which have been carefully examined. Magnetic fields up to 7300 gauss are produced in a solenoid giving less than .1% variation in field strength over a length of 6 cm at the center. The current-field ratio K of the solenoid is determined, under operating conditions, in terms of the calculated ratios of measured single layer solenoids. The field strength. during exposure is given by the product of K and the solenoid current. Evaporation of Zn and Cd in the short (6 cm) positive column of a helium discharge gives the desired lines, the Zeeman patterns of which are photographed with a Fabry-Perot interferometer. Measurement of the separations at orders of interference in the neighborhood of 100,000 gives the following values: Cd λ 6439 : e/m = 1.7578 x 107 e m units ± .06% Zn λ 6362 : e/m = 1.7576 ± .05% These results are stated as e/m = (1.7577 ± .0017) x 107 abs e m units

Institutions

Publication Details

Journal
CaltechTHESIS (California Institute of Technology)
Published
2024-08-29
DOI
https://doi.org/10.7907/5s2m-6b11
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Determination of e/m from the Zeeman Effect

CaltechTHESIS (California Institute of Technology)
Atomic and Subatomic Physics Research
article

A Determination of e/m from the Zeeman Effect

article en

Abstract

Values of e/m have been obtained from the Zeeman separations of the Cd line λ 6439 and the Zn line λ 6362, the g-factors of which have been carefully examined. Magnetic fields up to 7300 gauss are produced in a solenoid giving less than .1% variation in field strength over a length of 6 cm at the center. The current-field ratio K of the solenoid is determined, under operating conditions, in terms of the calculated ratios of measured single layer solenoids. The field strength. during exposure is given by the product of K and the solenoid current. Evaporation of Zn and Cd in the short (6 cm) positive column of a helium discharge gives the desired lines, the Zeeman patterns of which are photographed with a Fabry-Perot interferometer. Measurement of the separations at orders of interference in the neighborhood of 100,000 gives the following values: Cd λ 6439 : e/m = 1.7578 x 107 e m units ± .06% Zn λ 6362 : e/m = 1.7576 ± .05% These results are stated as e/m = (1.7577 ± .0017) x 107 abs e m units

CaltechTHESIS (California Institute of Technology)
California Institute of Technology (US)
Openalex Percentile: Top 73%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.