Laboratory evaluation of hourly mass concentration by PM<sub>2.5</sub> monitors using a mobility particle size spectrometer

The applicability of the mobility particle size spectrometer (MPSS) as a secondary reference for evaluating the accuracy of hourly PM<sub>2.5</sub> mass concentrations measured by automated continuous monitors (ACMs) was investigated under controlled laboratory conditions. Polystyrene and ammonium sulfate aerosols were used as test aerosols. First, MPSS measurements were compared with the primary gravimetric method based on 3-h averages to determine correction factors and measurement uncertainties for the MPSS. Then, corrected MPSS concentrations were used to assess three ACMs: two beta attenuation monitors (BAMs) and one tapered element oscillating microbalance (TEOM) monitor. Two evaluation approaches were used. The first examined trueness and repeatability of hourly concentrations at a constant concentration of 80–100 µg/m³. ACMs generally agreed with MPSS within 10%, though some deviations exceeded MPSS uncertainty (5%). Relative standard deviations were approximately 2% for BAMs and 4–5% for TEOM. The second assessed linearity and time response of hourly concentrations across 10–160 µg/m³, yielding regression slopes within 10% of unity and R<sup>2</sup> &gt; 0.999 for all ACMs. These results demonstrate that MPSS can serve as a secondary reference for ACM accuracy evaluations in laboratory tests, potentially supplementing costly ambient comparability studies. The capabilities and limitations of MPSS as a mass concentration reference are discussed. Copyright © 2025 American Association for Aerosol Research

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.29613823
Primary Topic
Air Quality and Health Impacts
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laboratory evaluation of hourly mass concentration by PM2.5 monitors using a mobility particle size spectrometer

Figshare
Air Quality and Health Impacts
article

Laboratory evaluation of hourly mass concentration by PM2.5 monitors using a mobility particle size spectrometer

article en

Abstract

The applicability of the mobility particle size spectrometer (MPSS) as a secondary reference for evaluating the accuracy of hourly PM<sub>2.5</sub> mass concentrations measured by automated continuous monitors (ACMs) was investigated under controlled laboratory conditions. Polystyrene and ammonium sulfate aerosols were used as test aerosols. First, MPSS measurements were compared with the primary gravimetric method based on 3-h averages to determine correction factors and measurement uncertainties for the MPSS. Then, corrected MPSS concentrations were used to assess three ACMs: two beta attenuation monitors (BAMs) and one tapered element oscillating microbalance (TEOM) monitor. Two evaluation approaches were used. The first examined trueness and repeatability of hourly concentrations at a constant concentration of 80–100 µg/m³. ACMs generally agreed with MPSS within 10%, though some deviations exceeded MPSS uncertainty (5%). Relative standard deviations were approximately 2% for BAMs and 4–5% for TEOM. The second assessed linearity and time response of hourly concentrations across 10–160 µg/m³, yielding regression slopes within 10% of unity and R<sup>2</sup> &gt; 0.999 for all ACMs. These results demonstrate that MPSS can serve as a secondary reference for ACM accuracy evaluations in laboratory tests, potentially supplementing costly ambient comparability studies. The capabilities and limitations of MPSS as a mass concentration reference are discussed. Copyright © 2025 American Association for Aerosol Research

Figshare
Openalex Percentile: Top 48%
Air Quality and Health Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laboratory evaluation of hourly mass concentration by PM<sub>2.5</sub> monitors using a mobility particle size spectrometer · Figshare (2025) | TGRS Research Map | TGRS