Determination of Sub-Nanomolar Manganese in Seawater Using Sequential Injection Chemiluminescence Detection with Nitrilotriacetic Acid (NTA) Resin for Matrix Separation

A novel sub-nanomolar Mn(II) determination method is reported, which integrates sequential injection analysis (SIA), chemiluminescence (CL) detection, and a nitrilotriacetic acid (NTA) resin column. Using the SIA technique reduces the consumption of reagents and samples to only 600 and 100 μL per analysis, respectively. Incorporating an NTA resin column eliminates the need for pH adjustment during the measurement process. Under optimized conditions, the detection limit of 0.17 nmol L<sup>−1</sup> and a linear calibration between CL intensity and Mn(II) concentrations (0-100 nmol L<sup>−1</sup>) was achieved. This method was applied to the certified seawater reference material NASS-7 and real seawater samples.

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.28589234.v1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Sub-Nanomolar Manganese in Seawater Using Sequential Injection Chemiluminescence Detection with Nitrilotriacetic Acid (NTA) Resin for Matrix Separation

Figshare
Analytical chemistry methods development
article

Determination of Sub-Nanomolar Manganese in Seawater Using Sequential Injection Chemiluminescence Detection with Nitrilotriacetic Acid (NTA) Resin for Matrix Separation

article en

Abstract

A novel sub-nanomolar Mn(II) determination method is reported, which integrates sequential injection analysis (SIA), chemiluminescence (CL) detection, and a nitrilotriacetic acid (NTA) resin column. Using the SIA technique reduces the consumption of reagents and samples to only 600 and 100 μL per analysis, respectively. Incorporating an NTA resin column eliminates the need for pH adjustment during the measurement process. Under optimized conditions, the detection limit of 0.17 nmol L<sup>−1</sup> and a linear calibration between CL intensity and Mn(II) concentrations (0-100 nmol L<sup>−1</sup>) was achieved. This method was applied to the certified seawater reference material NASS-7 and real seawater samples.

Figshare
Life below water
Openalex Percentile: Top 55%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.