Evaluating the ingress of total polycyclic aromatic hydrocarbons (PAHs) specifically naphthalene through firefighter hoods and base layers

Structural firefighters are exposed to an array of polycyclic aromatic hydrocarbons (PAHs) as a result of incomplete combustion of both synthetic and natural materials. PAHs are found in both the particulate and vapor phases in the firefighting environment and are significantly associated with acute and chronic diseases, including cancer. Using a fireground exposure simulator (FES) and standing mannequins dressed in four different firefighter personal protective equipment (PPE) conditions, each with varying levels of protective hood interface and particulate-blocking features, the efficacy of the hoods was assessed against the ingress of PAHs (specifically, naphthalene). The authors also explored the effectiveness of a 100% cotton turtleneck at further attenuating the amount of naphthalene reaching the surface of the mannequin’s neck. Air samples were collected at the breathing zone, abdomen, and thigh heights from the 6 ft-2 in mannequins used in this study. Naphthalene was the most abundant PAH (55% of the total PAH concentrations) in the FES and existed primarily in the vapor phase (92% vapor in the breathing zone). Additionally, bulk base layer and under the base layer polytetrafluoroethylene (PTFE) filter samples (used as skin surrogates) were collected from the neck region of the mannequins and analyzed for PAHs. A larger percentage of naphthalene was collected on the filter under the traditional knit hoods than on the cotton base layer, suggesting a small protective effect of the base layer against solid-phase naphthalene. Previous studies investigating naphthalene by employing air sampling under PPE have found a larger protective effect of base layers against the ingress of naphthalene vapor. PAHs that exist primarily as particulate in the fire environment were largely not detected on the base layers or PTFE filters under the gear. Further research is needed that involves more sensitive methods and non-static human subjects.

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.28144123.v1
Primary Topic
Occupational Health and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the ingress of total polycyclic aromatic hydrocarbons (PAHs) specifically naphthalene through firefighter hoods and base layers

Figshare
Occupational Health and Performance
article

Evaluating the ingress of total polycyclic aromatic hydrocarbons (PAHs) specifically naphthalene through firefighter hoods and base layers

article en

Abstract

Structural firefighters are exposed to an array of polycyclic aromatic hydrocarbons (PAHs) as a result of incomplete combustion of both synthetic and natural materials. PAHs are found in both the particulate and vapor phases in the firefighting environment and are significantly associated with acute and chronic diseases, including cancer. Using a fireground exposure simulator (FES) and standing mannequins dressed in four different firefighter personal protective equipment (PPE) conditions, each with varying levels of protective hood interface and particulate-blocking features, the efficacy of the hoods was assessed against the ingress of PAHs (specifically, naphthalene). The authors also explored the effectiveness of a 100% cotton turtleneck at further attenuating the amount of naphthalene reaching the surface of the mannequin’s neck. Air samples were collected at the breathing zone, abdomen, and thigh heights from the 6 ft-2 in mannequins used in this study. Naphthalene was the most abundant PAH (55% of the total PAH concentrations) in the FES and existed primarily in the vapor phase (92% vapor in the breathing zone). Additionally, bulk base layer and under the base layer polytetrafluoroethylene (PTFE) filter samples (used as skin surrogates) were collected from the neck region of the mannequins and analyzed for PAHs. A larger percentage of naphthalene was collected on the filter under the traditional knit hoods than on the cotton base layer, suggesting a small protective effect of the base layer against solid-phase naphthalene. Previous studies investigating naphthalene by employing air sampling under PPE have found a larger protective effect of base layers against the ingress of naphthalene vapor. PAHs that exist primarily as particulate in the fire environment were largely not detected on the base layers or PTFE filters under the gear. Further research is needed that involves more sensitive methods and non-static human subjects.

Figshare
Openalex Percentile: Top 40%
Occupational Health and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluating the ingress of total polycyclic aromatic hydrocarbons (PAHs) specifically naphthalene through firefighter hoods and base layers · Figshare (2025) | TGRS Research Map | TGRS